Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 5 van 12 gevonden artikelen
 
 
  Dilute-and-shoot procedure for the determination of mineral constituents in vinegar samples by axially viewed inductively coupled plasma optical emission spectrometry (ICP OES)
 
 
Titel: Dilute-and-shoot procedure for the determination of mineral constituents in vinegar samples by axially viewed inductively coupled plasma optical emission spectrometry (ICP OES)
Auteur: Silva, J. C. J. Da
Cadore, S.
Nobrega, J. A.
Baccan, N.
Verschenen in: Food additives and contaminants. Pt. A, Chemistry, analysis, control, exposure & risk assessment
Paginering: Jaargang 24 (2007) nr. 2 pagina's 130-139
Jaar: 2007-02
Inhoud: Samples of commercial wine vinegar were introduced in an axially viewed inductively coupled plasma optical emission spectrometry instrument (AX-ICP OES) equipped with different sample introduction systems: a cross-flow nebulizer combined with a double-path spray chamber (CF-DP) and cone spray associated with a cyclone spray chamber (CS-CC). Samples of white and red wine vinegar were diluted with water before analysis. Higher magnesium Mg II/Mg I ratios (11 and 10 for CS-CC and CF-DP, respectively) were obtained using a nebulization gas flow rate of 0.6 l min-1 and an applied power of 1.3 kW. The background equivalent concentrations (BEC) and signal-to-background ratio (SBR) of analytes were improved using scandium (Sc) as the internal standard. The limits of detection (LOD) and limits of quantification (LOQ) for mineral constituents were similar for both introduction systems. Best recoveries values were obtained using a plasma under robust conditions, CS-CC system and Sc as the internal standard. The concentration determined in 13 commercial samples of wine vinegars varied between 0.2 and 3.0, between 0.02 and 0.4, between 8.5 and 100.0, between 0.01 and 0.05, between 27.0 and 540.0, between 4.0 and 79.0, between 0.4 and 10.0, and between 0.01 and 2.0 for aluminium (Al), barium (Ba), calcium (Ca), copper (Cu), potassium (K), magnesium (Mg), manganese (Mn), and zinc (Zn), respectively.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 5 van 12 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland