Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 9 van 13 gevonden artikelen
 
 
  Evaluation of active video games intensity: Comparison between accelerometer-based predictions and indirect calorimetric measurements
 
 
Titel: Evaluation of active video games intensity: Comparison between accelerometer-based predictions and indirect calorimetric measurements
Auteur: Tripette, Julien
Ando, Takafumi
Murakami, Haruka
Yamamoto, Kenta
Ohkawara, Kazunori
Tanaka, Shigeho
Miyachi, Motohiko
Verschenen in: Technology & health care
Paginering: Jaargang 22 (2014) nr. 2 pagina's 199-208
Jaar: 2014-06-04
Inhoud: BACKGROUND: Several active video game (AVG) intervention studies failed in showing an increase in physical activity by using accelerometry measurements. OBJECTIVE: To test the validity of accelerometry for monitoring AVG playing intensity. METHOD: Twenty-two adults performed 80 activities included in the Wii Sports and Wii Fit Plus series. The energy expenditure (EE) and subsequent MET values were measured by indirect calorimetry using metabolic chambers. Subjects wore an accelerometer-based monitor displaying MET values. For each activity, METs values obtained from indirect calorimetry and accelerometry were compared. Each activity was classified as light or moderate to vigorous physical activity (LPA: < 3METs or MVPA: ⩾ 3METs) for the two methods. RESULTS: AVG intensities have been slightly but significantly underestimated by the acceleromater-based monitor compared to the indirect calorimetry (2.5 ± 1.0 instead of 2.7 ± 0.9 METs). Fourty percent of activities have been significantly misestimated, and 20% have been misclassified. CONCLUSION: Those results point out the potential bias of accelerometry measurements for evaluating AVG intensities. Because average AVG intensity lays at the boundary between LPA and MVPA classes, misclassifications can frequently occur. Accelerometry data should be interpreted with caution in intervention studies using AVG.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 9 van 13 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland