Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 15 van 56 gevonden artikelen
 
 
  External abdominal oblique muscle ultrasonographic thickness changes is not an appropriate surrogate measure of electromyographic activity during isometric trunk contractions
 
 
Titel: External abdominal oblique muscle ultrasonographic thickness changes is not an appropriate surrogate measure of electromyographic activity during isometric trunk contractions
Auteur: Rabello, Lucas M.
Gagnon, Dany
da Silva, Rubens A.
Paquette, Philippe
Larivière, Christian
Verschenen in: Journal of back and musculoskeletal rehabilitation
Paginering: Jaargang 28 (2014) nr. 2 pagina's 229-238
Jaar: 2014-08-13
Inhoud: BACKGROUND: The function of specific abdominal muscles can be assessed using both electromyography (EMG) and ultrasound imaging (USI) thickness measures. However, the relationship between these two measurements is not conclusive during sitting isometric trunk efforts. OBJECTIVE: This study was conducted to assess the relationship between USI thickness and EMG amplitude measures of the right external oblique (EO) muscle during isometric efforts in the sitting position. METHOD: Eighteen subjects performed ramp isometric efforts progressing from 0 to 50% of their maximal voluntary contraction (MVC) in three trunk directions on a dynamometer: (1) forward flexion; (2) right lateral flexion; and (3) left axial rotation. USI and surface EMG amplitude measures of the EO muscle were recorded concomitantly and both normalized against rest values and maximal EMG, respectively. RESULTS: EO muscle was significantly more activated (p < 0.001) during forward flexion (42% on average) and axial rotation (35%) than during lateral flexion (24%). Non-significant (r=0.01; P=0.979) to highly significant (r=0.98; P < 0.0001) and negative and positive Pearson correlations were observed between EMG and EO thickness measures for both flexion and rotation directions. CONCLUSION: The negative correlations between EMG and USI measures as well as the great variability of these correlations across individuals suggest that USI is not a valid measures of EO muscle activity. USI thickness measures should be interpreted with great caution in research and clinical settings.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 15 van 56 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland