Digital Library
Close Browse articles from a journal
 
<< previous    next >>
     Journal description
       All volumes of the corresponding journal
         All issues of the corresponding volume
           All articles of the corresponding issues
                                       Details for article 15 of 56 found articles
 
 
  External abdominal oblique muscle ultrasonographic thickness changes is not an appropriate surrogate measure of electromyographic activity during isometric trunk contractions
 
 
Title: External abdominal oblique muscle ultrasonographic thickness changes is not an appropriate surrogate measure of electromyographic activity during isometric trunk contractions
Author: Rabello, Lucas M.
Gagnon, Dany
da Silva, Rubens A.
Paquette, Philippe
Larivière, Christian
Appeared in: Journal of back and musculoskeletal rehabilitation
Paging: Volume 28 (2014) nr. 2 pages 229-238
Year: 2014-08-13
Contents: BACKGROUND: The function of specific abdominal muscles can be assessed using both electromyography (EMG) and ultrasound imaging (USI) thickness measures. However, the relationship between these two measurements is not conclusive during sitting isometric trunk efforts. OBJECTIVE: This study was conducted to assess the relationship between USI thickness and EMG amplitude measures of the right external oblique (EO) muscle during isometric efforts in the sitting position. METHOD: Eighteen subjects performed ramp isometric efforts progressing from 0 to 50% of their maximal voluntary contraction (MVC) in three trunk directions on a dynamometer: (1) forward flexion; (2) right lateral flexion; and (3) left axial rotation. USI and surface EMG amplitude measures of the EO muscle were recorded concomitantly and both normalized against rest values and maximal EMG, respectively. RESULTS: EO muscle was significantly more activated (p < 0.001) during forward flexion (42% on average) and axial rotation (35%) than during lateral flexion (24%). Non-significant (r=0.01; P=0.979) to highly significant (r=0.98; P < 0.0001) and negative and positive Pearson correlations were observed between EMG and EO thickness measures for both flexion and rotation directions. CONCLUSION: The negative correlations between EMG and USI measures as well as the great variability of these correlations across individuals suggest that USI is not a valid measures of EO muscle activity. USI thickness measures should be interpreted with great caution in research and clinical settings.
Publisher: IOS Press
Source file: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details for article 15 of 56 found articles
 
<< previous    next >>
 
 Koninklijke Bibliotheek - National Library of the Netherlands