nr |
titel |
auteur |
tijdschrift |
jaar |
jaarg. |
afl. |
pagina('s) |
type |
1 |
A comparative study of mechanical properties of fresh and frozen-thawed porcine intervertebral discs in a bioreactor environment
|
Azarnoosh, M. |
|
2017 |
69 |
C |
p. 169-177 |
artikel |
2 |
A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: A finite element wear analysis
|
Ashkanfar, Ariyan |
|
2017 |
69 |
C |
p. 257-266 |
artikel |
3 |
A method and a device for the evaluation of the retention of telescopic dental crowns
|
Majcher, Andrzej |
|
2017 |
69 |
C |
p. 362-367 |
artikel |
4 |
Analyzing the effect of hydration on the wedge indentation fracture behavior of cortical bone
|
Hoffseth, Kevin |
|
2017 |
69 |
C |
p. 318-326 |
artikel |
5 |
A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation
|
Ackland, David C. |
|
2017 |
69 |
C |
p. 404-411 |
artikel |
6 |
A representative volume element based micromechanical analysis of a Bi-layered Ganoid Fish scale
|
Nelms, Matthew |
|
2017 |
69 |
C |
p. 395-403 |
artikel |
7 |
Bioactivity, cytocompatibility and thermal properties of experimental Bioglass-reinforced composites as potential root-canal filling materials
|
Alhashimi, Raghad Abdulrazzaq |
|
2017 |
69 |
C |
p. 355-361 |
artikel |
8 |
Biomechanics of the human intervertebral disc: A review of testing techniques and results
|
Newell, N. |
|
2017 |
69 |
C |
p. 420-434 |
artikel |
9 |
Composition dependent mechanical behaviour of S53P4 bioactive glass putty for bone defect grafting
|
van Gestel, N.A.P. |
|
2017 |
69 |
C |
p. 301-306 |
artikel |
10 |
Comprehensive mechanical characterization of PLA fabric combined with PCL to form a composite structure vascular graft
|
Li, Chaojing |
|
2017 |
69 |
C |
p. 39-49 |
artikel |
11 |
Discrete quasi-linear viscoelastic damping analysis of connective tissues, and the biomechanics of stretching
|
Babaei, Behzad |
|
2017 |
69 |
C |
p. 193-202 |
artikel |
12 |
Dynamic measurement of surface strain distribution on the foot during walking
|
Ito, Kohta |
|
2017 |
69 |
C |
p. 249-256 |
artikel |
13 |
Editorial board/Aims and Scope
|
|
|
2017 |
69 |
C |
p. IFC |
artikel |
14 |
Effect of root morphology on the susceptibility of endodontically treated teeth to vertical root fracture: An ex-vivo model
|
Pilo, Raphael |
|
2017 |
69 |
C |
p. 267-274 |
artikel |
15 |
Effects of precursor composition and mode of crosslinking on mechanical properties of graphene oxide reinforced composite hydrogels
|
Jang, Jinhyeong |
|
2017 |
69 |
C |
p. 282-293 |
artikel |
16 |
Expression, crosslinking, and developing modulus master curves of recombinant resilin
|
Khandaker, Md Shahriar K. |
|
2017 |
69 |
C |
p. 385-394 |
artikel |
17 |
Factors affecting the mechanical behavior of collagen hydrogels for skin tissue engineering
|
Pensalfini, Marco |
|
2017 |
69 |
C |
p. 85-97 |
artikel |
18 |
Fatigue life of bovine meniscus under longitudinal and transverse tensile loading
|
Creechley, Jaremy J. |
|
2017 |
69 |
C |
p. 185-192 |
artikel |
19 |
Fatigue limits of different PEEK materials for dental implants
|
Schwitalla, Andreas Dominik |
|
2017 |
69 |
C |
p. 163-168 |
artikel |
20 |
Fatigue responses of the human cervical spine intervertebral discs
|
Yoganandan, Narayan |
|
2017 |
69 |
C |
p. 30-38 |
artikel |
21 |
Formation of porous HPCL/LPCL/HA scaffolds with supercritical CO2 gas foaming method
|
Moghadam, M. Zahedi |
|
2017 |
69 |
C |
p. 115-127 |
artikel |
22 |
Freeform extrusion fabrication of titanium fiber reinforced 13–93 bioactive glass scaffolds
|
Thomas, Albin |
|
2017 |
69 |
C |
p. 153-162 |
artikel |
23 |
In situ observation of lubricant film formation in THR considering real conformity: The effect of diameter, clearance and material
|
Nečas, D. |
|
2017 |
69 |
C |
p. 66-74 |
artikel |
24 |
Investigation of inhomogeneous and anisotropic material behavior of porcine thoracic aorta using nano-indentation tests
|
Kermani, Golriz |
|
2017 |
69 |
C |
p. 50-56 |
artikel |
25 |
Mechanical characteristics of nanocellulose-PEG bionanocomposite wound dressings in wet conditions
|
Sun, Fengzhen |
|
2017 |
69 |
C |
p. 377-384 |
artikel |
26 |
Microscopic full-field three-dimensional strain measurement during the mechanical testing of additively manufactured porous biomaterials
|
Genovese, Katia |
|
2017 |
69 |
C |
p. 327-341 |
artikel |
27 |
Microstructural evolution and mechanical property of Ti-6Al-4V wall deposited by continuous plasma arc additive manufacturing without post heat treatment
|
Lin, Jianjun |
|
2017 |
69 |
C |
p. 19-29 |
artikel |
28 |
Microstructural, mechanical and corrosion characteristics of heat-treated Mg-1.2Zn-0.5Ca (wt%) alloy for use as resorbable bone fixation material
|
Ibrahim, Hamdy |
|
2017 |
69 |
C |
p. 203-212 |
artikel |
29 |
Mobility and shape adaptation of neutrophil in the microchannel flow
|
Czerwinska, Justyna |
|
2017 |
69 |
C |
p. 294-300 |
artikel |
30 |
New regime in the mechanical behavior of skin: strain-softening occurring before strain-hardening
|
Nicolle, S. |
|
2017 |
69 |
C |
p. 98-106 |
artikel |
31 |
On the mechanical behaviour of PEEK and HA cranial implants under impact loading
|
Garcia-Gonzalez, D. |
|
2017 |
69 |
C |
p. 342-354 |
artikel |
32 |
On the synthesis of nanostructured akermanite scaffolds via space holder method: The effect of the spacer size on the porosity and mechanical properties
|
Najafinezhad, Aliakbar |
|
2017 |
69 |
C |
p. 242-248 |
artikel |
33 |
Osseodensification for enhancement of spinal surgical hardware fixation
|
Lopez, Christopher D. |
|
2017 |
69 |
C |
p. 275-281 |
artikel |
34 |
Polymerization kinetics of n-butyl cyanoacrylate glues used for vascular embolization
|
Li, Y.J. |
|
2017 |
69 |
C |
p. 307-317 |
artikel |
35 |
Processing and mechanical characteristics of magnesium-hydroxyapatite metal matrix biocomposites
|
del Campo, R. |
|
2017 |
69 |
C |
p. 135-143 |
artikel |
36 |
Promising characteristics of gradient porosity Ti-6Al-4V alloy prepared by SLM process
|
Fousová, Michaela |
|
2017 |
69 |
C |
p. 368-376 |
artikel |
37 |
PVA matches human liver in needle-tissue interaction
|
de Jong, Tonke L. |
|
2017 |
69 |
C |
p. 223-228 |
artikel |
38 |
Reinforcement of a PMMA resin for interim fixed prostheses with silica nanoparticles
|
Topouzi, Marianthi |
|
2017 |
69 |
C |
p. 213-222 |
artikel |
39 |
Shear waves elastography for assessment of human Achilles tendon's biomechanical properties: an experimental study
|
Haen, T.X. |
|
2017 |
69 |
C |
p. 178-184 |
artikel |
40 |
Strong synergistic effects in PLA/PCL blends: Impact of PLA matrix viscosity
|
Ostafinska, Aleksandra |
|
2017 |
69 |
C |
p. 229-241 |
artikel |
41 |
Systematic mechanical evaluation of electrospun gelatin meshes
|
Butcher, Annabel L. |
|
2017 |
69 |
C |
p. 412-419 |
artikel |
42 |
The effect of phosphoric and phosphonic acid primers on bone cement bond strength to total hip stem alloys
|
Jakubowitz, Eike |
|
2017 |
69 |
C |
p. 57-65 |
artikel |
43 |
The impact of metastasis on the mineral phase of vertebral bone tissue
|
Burke, Mikhail |
|
2017 |
69 |
C |
p. 75-84 |
artikel |
44 |
Toward improved mechanical, tribological, corrosion and in-vitro bioactivity properties of mixed oxide nanotubes on Ti–6Al–7Nb implant using multi-objective PSO
|
Rafieerad, A.R. |
|
2017 |
69 |
C |
p. 1-18 |
artikel |
45 |
Tribocorrosion behavior of bio-functionalized highly porous titanium
|
Toptan, F. |
|
2017 |
69 |
C |
p. 144-152 |
artikel |
46 |
Tribological behavior of Ti6Al4V cellular structures produced by Selective Laser Melting
|
Bartolomeu, F. |
|
2017 |
69 |
C |
p. 128-134 |
artikel |
47 |
Why do some titanium-alloy total hip arthroplasty modular necks fail?
|
Fokter, Samo K. |
|
2017 |
69 |
C |
p. 107-114 |
artikel |