Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
                                       Alle artikelen van de bijbehorende aflevering
 
                             22 gevonden resultaten
nr titel auteur tijdschrift jaar jaarg. afl. pagina('s) type
1 Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices Birschmann, Ingvild
2014
33 1 p. 80-87
8 p.
artikel
2 An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial Najjar, Samer S.
2014
33 1 p. 23-34
12 p.
artikel
3 A novel link between G6PD deficiency and hemolysis in patients with continuous-flow left ventricular assist devices Alhosaini, Hassan
2014
33 1 p. 116-117
2 p.
artikel
4 Aortic valve opening and thrombotic events with continuous-flow left ventricular assist devices Saeed, Omar
2014
33 1 p. 109-112
4 p.
artikel
5 Carotid-bulb thrombus and continuous-flow left ventricular assist devices: A novel observation Reul, John T.
2014
33 1 p. 107-109
3 p.
artikel
6 Continuous-flow left ventricular assist device exchange: Clinical outcomes Ota, Takeyoshi
2014
33 1 p. 65-70
6 p.
artikel
7 Continuous flow left ventricular assist device related aortic root thrombosis complicated by left main coronary artery occlusion Shah, Sachin
2014
33 1 p. 119-120
2 p.
artikel
8 Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: A multifactorial phenomenon Uriel, Nir
2014
33 1 p. 51-59
9 p.
artikel
9 Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support Shah, Palak
2014
33 1 p. 102-104
3 p.
artikel
10 Editorial Board 2014
33 1 p. A1-
1 p.
artikel
11 Fondaparinux: An effective bridging strategy in heparin-induced thrombocytopenia and mechanical circulatory support Gellatly, Rochelle M.
2014
33 1 p. 118-
1 p.
artikel
12 Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device Stulak, John M.
2014
33 1 p. 60-64
5 p.
artikel
13 Hemolysis: A harbinger of adverse outcome after left ventricular assist device implant Cowger, Jennifer A.
2014
33 1 p. 35-43
9 p.
artikel
14 Hemolysis in left ventricular assist device: A retrospective analysis of outcomes Ravichandran, Ashwin K.
2014
33 1 p. 44-50
7 p.
artikel
15 Incidence of increases in pump power use and associated clinical outcomes with an axial continuous-flow ventricular assist device Steffen, Robert J.
2014
33 1 p. 105-106
2 p.
artikel
16 Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device Kirklin, James K.
2014
33 1 p. 12-22
11 p.
artikel
17 Low-molecular-weight heparin for anti-coagulation after left ventricular assist device implantation Sandner, Sigrid E.
2014
33 1 p. 88-93
6 p.
artikel
18 Myocardial infarction after left ventricular assist device implantation: Clinical course, role of aortic root thrombus, and outcomes Fried, Justin
2014
33 1 p. 112-115
4 p.
artikel
19 Notice of Retraction 2014
33 1 p. 121-
1 p.
artikel
20 Platelet glycoprotein IbĪ± ectodomain shedding and non-surgical bleeding in heart failure patients supported by continuous-flow left ventricular assist devices Hu, Jingping
2014
33 1 p. 71-79
9 p.
artikel
21 The use of eptifibatide for suspected pump thrombus or thrombosis in patients with left ventricular assist devices Tellor, Bethany R.
2014
33 1 p. 94-101
8 p.
artikel
22 The vexing problem of thrombosis in long-term mechanical circulatory support Mehra, Mandeep R.
2014
33 1 p. 1-11
11 p.
artikel
                             22 gevonden resultaten
 