nr |
titel |
auteur |
tijdschrift |
jaar |
jaarg. |
afl. |
pagina('s) |
type |
1 |
A combined computational and experimental approach to assess the transfer function of real pacemaker leads for MR radiofrequency-induced heating
|
Mattei, Eugenio |
|
|
34 |
4 |
p. 619-630 |
artikel |
2 |
A new technique to evaluate the impact of running on knee cartilage deformation by region
|
Brenneman Wilson, Elora C. |
|
|
34 |
4 |
p. 593-603 |
artikel |
3 |
A physical phantom for amine chemical exchange saturation transfer (CEST) MRI
|
Yao, Jingwen |
|
|
34 |
4 |
p. 569-580 |
artikel |
4 |
Comparing multiband and singleband EPI in NODDI at 3 T: what are the implications for reproducibility and study sample sizes?
|
Bouyagoub, Samira |
|
|
34 |
4 |
p. 499-511 |
artikel |
5 |
Contribution of preclinical MRI to responsible animal research: living up to the 3R principle
|
Wachsmuth, Lydia |
|
|
34 |
4 |
p. 469-474 |
artikel |
6 |
3D magnetization transfer (MT) for the visualization of cardiac free-running Purkinje fibers: an ex vivo proof of concept
|
Magat, Julie |
|
|
34 |
4 |
p. 605-618 |
artikel |
7 |
Effect of MRI acquisition acceleration via compressed sensing and parallel imaging on brain volumetry
|
Dieckmeyer, Michael |
|
|
34 |
4 |
p. 487-497 |
artikel |
8 |
EGFR-specific single-chain variable fragment antibody-conjugated Fe3O4/Au nanoparticles as an active MRI contrast agent for NSCLC
|
Lu, Yuan |
|
|
34 |
4 |
p. 581-591 |
artikel |
9 |
ESMRMB annual meeting roundtable discussion: “Challenges and solutions in data sharing—an MRI perspective”
|
Kan, Hermien E. |
|
|
34 |
4 |
p. 483-486 |
artikel |
10 |
ESMRMB annual meeting roundtable discussion: “when less is more: the view of MRI vendors on low-field MRI”
|
Marques, José P. |
|
|
34 |
4 |
p. 479-482 |
artikel |
11 |
Image distortion correction for MRI in low field permanent magnet systems with strong B0 inhomogeneity and gradient field nonlinearities
|
Koolstra, Kirsten |
|
|
34 |
4 |
p. 631-642 |
artikel |
12 |
Impact of the acquisition protocol on the sensitivity to demyelination and axonal loss of clinically feasible DWI techniques: a simulation study
|
Oliviero, Stefania |
|
|
34 |
4 |
p. 523-543 |
artikel |
13 |
Integrated slice-specific dynamic shimming for whole-body diffusion-weighted MR imaging at 1.5 T
|
McElroy, Sarah |
|
|
34 |
4 |
p. 513-521 |
artikel |
14 |
Simulated basis sets for semi-LASER: the impact of including shaped RF pulses and magnetic field gradients
|
Jalnefjord, Oscar |
|
|
34 |
4 |
p. 545-554 |
artikel |
15 |
This house proposes that low field and high field MRI are by destiny worst enemies, and can never be the best of friends!
|
Norris, David Gordon |
|
|
34 |
4 |
p. 475-477 |
artikel |
16 |
3T MEGA-PRESS study of N-acetyl aspartyl glutamate and N-acetyl aspartate in activated visual cortex
|
Manzhurtsev, Andrei |
|
|
34 |
4 |
p. 555-568 |
artikel |