  Assessment of dose due to exposure to indoor radon and thoron progeny
 
 
Titel: Assessment of dose due to exposure to indoor radon and thoron progeny
Auteur: Prasad Ganesh
Gusain Gurupad S.
Joshi Veena
Ramola Rakesh C.
Verschenen in: Nuclear technology & radiation protection
Paginering: Jaargang 25 (2010) nr. 3 pagina's 198-204
Jaar: 2010
Inhoud: The components of the effective dose through inhalation from radon and its progeny are important for human health since they contribute to more than 50% of the total radiation dose from natural sources. As a consequence, radon has been identified as the second leading cause of lung cancer after smoking. Radon and its short lived decay products (218Po, 214Pb, 214Bi, 214Po) present in dwellings are a radiation hazard, particularly if such sources are concentrated in the enclosed areas like poorly ventilated houses and underground mines. The indoor radon, thoron, and progeny concentrations were measured in a small hilly town of Budhakedar and the surrounding area of Tehri Garhwal, India, by using LR-115 Type II plastic track detector in a twin cup radon dosimeter. The concentrations of radon progeny were measured as the highest in winter and the lowest in summer while the thoron progeny concentration was found maximum in rainy season and minimum in autumn. The annual exposure to the potential alpha energy of radon and thoron were found to vary from 0.04 WLM to 0.69 WLM with an average value of 0.29 WLM, and 0.03 WLM to 0.37 WLM with an aver- age value of 0.16 WLM, respectively. The annual effective dose due to the exposure to indoor radon and progeny in Budhakedar homes was found to vary from 0.16 mSv to 2.72 mSv with an average value of 1.14 mSv and the effective dose due to the exposure to thoron and progeny was found to vary from 0.18 mSv to 2.49 mSv with an average value of 1.05 mSv. The results of systematic study have been obtained by considering the room as a space in which the radon and thoron levels are directly related to the dynamic and static parameters.
Uitgever: VINČA Institute of Nuclear Sciences (provided by DOAJ)
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 7 van 23 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland