Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 17 van 35 gevonden artikelen
 
 
  Effects of Forest Thinning on Direct Runoff and Peak Runoff Properties in a Small Mountainous Watershed in Kochi Prefecture, Japan
 
 
Titel: Effects of Forest Thinning on Direct Runoff and Peak Runoff Properties in a Small Mountainous Watershed in Kochi Prefecture, Japan
Auteur: Abu Farah Md. Anisur Rahman
Hiromasa Hiura
Kazuo Shino
Keiji Takase
Verschenen in: Pakistan journal of biological sciences
Paginering: Jaargang 8 (2005) nr. 2 pagina's 259-266
Jaar: 2005
Inhoud: Single catchment experiment was used to assess the effects of thinning on direct runoff and peak runoff properties in a small mountainous watershed of Kochi prefecture, Japan. The watershed is covered with commercial plantations of Japanese cedar (Cryptomeria japonica), Japanese cypress (Chamaecyparis obtusa), red pine (Pinus densiflora) and oak (Quercus spp.). Following an initial pre-thinning period (1996-1999), stream flow measurements were continued over a comparable post-thinning period (2000-2003) and linear regression models were developed for the two periods to assess the effects of a thinning operation conducted during December 1999 to January 2000. We hypothesized that the regression model for the pre-thinning period is still valid for the post-thinning period and tested this utilizing the Chow`s F Test. A 95% prediction interval was calculated for the pre-thinning regression models to evaluate changes in individual observations of the post-thinning period. The results suggest that the thinning, carried out on 19.25% of the watershed area removing only 6.35% of total timber volume, did not cause noticeable effects on direct runoff and peak runoff. Concentration time was found to be decreased after thinning for some storm events. The study revealed that hydrometric method is not enough for detecting noticeable effects of a small thinning operation on direct runoff and peak runoff properties.
Uitgever: Asian Network for Scientific Information (provided by DOAJ)
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 17 van 35 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland