Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 4 van 62 gevonden artikelen
 
 
  Analysis of Pesticide Residues in Fortified Water, Soil and Vegetable Samples
 
 
Titel: Analysis of Pesticide Residues in Fortified Water, Soil and Vegetable Samples
Auteur: Seema Tahir
Tahir Anwar
Shagufta Aziz
Rauf Ahmed Werer
Karam Ahad
Ashiq Mohammed
Erik K. Kirknel
Umar Khan Baloch
Verschenen in: Pakistan journal of biological sciences
Paginering: Jaargang 2 (1999) nr. 1 pagina's 233-235
Jaar: 1999
Inhoud: Water, soil and potato samples spiked with insecticides were analyzed for percent recoveries on Gas Chromatograph (GC) equipped with Electron Capture Detector (ECD), using capillary column. Percent recoveries of methyl parathion were calculated to be 100, 67 and 94 percent at spiking level of 0.17, 1.7 and 8.7 micro g/liter and 310 and 138 percent for cypermethrin at spiking level of 0.146 and 1.46 g/liter by liquid-liquid extraction. Through solid-phase extraction the percent recovery of deltamethrin was 37 and 78 percent at spiking level of 0.16 and 1.6 micro g/liter. The percent recoveries of deltamethrin through solvent extraction technique were found to be 78 and 86 percent at spiking level of 2.56 and 25.20 micro g/liter, while 81 and 147 percent for deltamethrin and cypermethrin through soxhlet extraction at 8.0 and 8.7 micro g/liter concentration respectively. The percent recoveries at spiking level of 0.1 ppm were calculated to be 0, 5.59, 35.52 and 0 percent, and in 1.00 ppm recovery was calculated to be 91.98, 56.60, 44.56 and 58.93 percent in fortified samples of potato with dimethoate, methyl parathion, endosulfan and cypermethrin, followed by 0, 59.82, 111.20, 11.36 percent in blank spiked at 0.1 ppm respectively. The data presented provides evidence that capillary column GC with ECD detection can be used reliably and advantageously for regulatory determination of pesticide residues in food, water and soil. The different methods described allow quantitative extraction of the pesticides. However, further experiments need to be conducted to ensure consistent results. The reproducibility of analytical methods require that the pesticide residue analysis be performed with the highest possible accuracy and so qualified that, the results obtain reflect the least deviation from the true value. <br>
Uitgever: Asian Network for Scientific Information (provided by DOAJ)
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 4 van 62 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland