Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 5 van 13 gevonden artikelen
 
 
  DEMANDA TOTAL DE ÁGUA DO FEIJOEIRO NOS SISTEMAS DE PLANTIO CONVENCIONAL E DIRETO TOTAL COMMON BEAN WATER DEMAND UNDER CONVENTIONAL AND NO-TILLAGE SYSTEMS
 
 
Titel: DEMANDA TOTAL DE ÁGUA DO FEIJOEIRO NOS SISTEMAS DE PLANTIO CONVENCIONAL E DIRETO TOTAL COMMON BEAN WATER DEMAND UNDER CONVENTIONAL AND NO-TILLAGE SYSTEMS
Auteur: Jorge Luiz do Nascimento
Luis Fernando Stone
Luiz Fernando Coutinho de Oliveira
Verschenen in: Pesquisa agropecuária tropical
Paginering: Jaargang 31 (2007) nr. 2 pagina's 159-161
Jaar: 2007
Inhoud: <!-- @page { margin: 2cm } --> <p class="western" align="justify">Em um experimento com cinco faixas de irrigação, obtidas por uma linha central de aspersão, determinou-se a demanda total de água do feijoeiro nos sistemas de plantio convencional e direto. O controle da irrigação foi feito por duas baterias de tensiômetros instaladas na segunda faixa paralela à linha de aspersão. O sistema de plantio direto proporcionou economia de 20% de água de irrigação em relação ao plantio convencional. A demanda total estimada com base na evaporação do tanque classe “A”, superestimou em 11,0% e 29,0% a demanda determinada por tensiometria para os sistemas de plantio convencional e direto, respectivamente.</p> <p class="western" align="justify">PALAVRAS-CHAVE: Plantio direto; tensiômetro; irrigação.</p> <!-- @page { margin: 2cm } --> <p class="western" align="justify">A line source with a five-band irrigation experiment was used to determined the total common bean water demand under conventional and no-tillage systems. Irrigation was controlled by two tensiometer sets installed in the second band parallel to the line source. The no-tillage system resulted in a 20% reduction in irrigation water demand as compared to the conventional system. The total estimated demand based on the class “A” evaporation tank overestimated the tensiometer determined demand for conventional and no-tillage systems by 11% and 29%, respectively.</p> <p class="western">KEY-WORDS: No-tillage; tensiometer; irrigation.</p>
Uitgever: Escola de Agronomia e Engenharia de Alimentos - UFG (provided by DOAJ)
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 5 van 13 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland