Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 9 van 32 gevonden artikelen
 
 
  COLETA DE SÊMEN OVINO EM ESTAÇÃO OU DECÚBITO LATERAL UTILIZANDO DIFERENTES ELETROEJACULADORES
 
 
Titel: COLETA DE SÊMEN OVINO EM ESTAÇÃO OU DECÚBITO LATERAL UTILIZANDO DIFERENTES ELETROEJACULADORES
Auteur: Ligia Freitas de Lima
Rodrigo Dorneles Tortorella
Diogo Ramos Leal
Pedro Ivo Braga Passos
Roberto Sartori
Thiago Antônio de Souza Nascimento Silva
Hetielle Harumi Hashimoto
Jairo Pereira Neves
Verschenen in: Ciéncia animal brasileira
Paginering: Jaargang 11 (2010) nr. 2 pagina's 410-416
Jaar: 2010
Inhoud: The objective of the experiment was to evaluate and comparetwo electroejaculators: an automatic one (A – Biocom Ltda.,Uberaba, MG) and a manual one (M – Duboi, Campo Grande,MS), using two methods of physical restrain: standing (E) or lateralrecumbency (D). Twelve rams were used: Santa Inês (n=9),Ile-de-France (n=2) and Texel (n=1). Semen were collected twicea week and each animal had the semen collected three times ineach group (AD – automatic in recumbency, AE – automatic instation, MD – manual in recumbency, and ME – manual in station)resulting in 12 collections. Blood samples were obtained before and after the semen collections to measure changes in circulatingcortisol in order to measure stress among groups and individuals.The collections were evaluated per the time in seconds to obtain seminalfraction, time of seminal fraction and percentage of rams thatexposed the penis. The collected semen parameters evaluated were:volume, aspect, progressive motility, wave motion, sperm vigor,total number of spermatozoa and sperm morphology. In 7.1% ofthe collections, there was no ejaculation, moreover, group AD wasresponsible for most of the collections without ejaculation (20%)(P<0,05). There was no difference among groups (P>0.05) relatingto cortisol level after collections. However, there was differenceamong individuals (P<0.05). The collections in lateral recumbencywere faster regarding achievement of seminal fraction and providedmore time length for seminal fraction. The MD group required ashorter time length to achieve the seminal fraction and produced agreater volume of ejaculate in comparison to the AS group. It canbe concluded by these results that both eletroejaculators (automaticand manual) had similar results as well as both methods of physicalrestrain (standing and lateral recumbency).
Uitgever: Universidade Federal de Goiás (provided by DOAJ)
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 9 van 32 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland