  A compact and stable eddy covariance set-up for methane measurements using off-axis integrated cavity output spectroscopy
 
 
Titel: A compact and stable eddy covariance set-up for methane measurements using off-axis integrated cavity output spectroscopy
Auteur: D. M. D. Hendriks
A. J. Dolman
M. K. van der Molen
J. van Huissteden
Verschenen in: Atmospheric chemistry and physics
Paginering: Jaargang 8 (2008) nr. 2 pagina's 431-443
Jaar: 2008
Inhoud: A Fast Methane Analyzer (FMA) is assessed for its applicability in a closed path eddy covariance field set-up in a peat meadow. The FMA uses off-axis integrated cavity output spectroscopy combined with a highly specific narrow band laser for the detection of CH<sub>4</sub> and strongly reflective mirrors to obtain a laser path length of 2–20×10<sup>3</sup> m. Statistical testing and a calibration experiment showed high precision (7.8×10<sup>−3</sup> ppb) and accuracy (<0.30%) of the instrument, while no drift was observed. The instrument response time was determined to be 0.10 s. In the field set-up, the FMA is attached to a scroll pump and combined with a 3-axis ultrasonic anemometer and an open path infrared gas analyzer for measurements of carbon dioxide and water vapour. The power-spectra and co-spectra of the instruments were satisfactory for 10 Hz sampling rates. <br><br> Due to erroneous measurements, spikes and periods of low turbulence the data series consisted for 26% of gaps. Observed CH<sub>4</sub> fluxes consisted mainly of emission, showed a diurnal cycle, but were rather variable over. The average CH<sub>4</sub> emission was 29.7 nmol m<sup>−2</sup> s<sup>−1</sup>, while the typical maximum CH<sub>4</sub> emission was approximately 80.0 nmol m<sup>−2</sup> s<sup>−1</sup> and the typical minimum flux was approximately 0.0 nmol m<sup>−2</sup> s<sup>−1</sup>. The correspondence of the measurements with flux chamber measurements in the footprint was good and the observed CH<sub>4</sub> emission rates were comparable with eddy covariance CH<sub>4</sub> measurements in other peat areas. <br><br> Additionally, three measurement techniques with lower sampling frequencies were simulated, which might give the possibility to measure CH<sub>4</sub> fluxes without an external pump and save energy. Disjunct eddy covariance appeared to be the most reliable substitute for 10 Hz eddy covariance, while relaxed eddy accumulation gave reliable estimates of the fluxes over periods in the order of days or weeks.
Uitgever: Copernicus GmbH (provided by DOAJ)
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 