Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 9 van 32 gevonden artikelen
 
 
  GOMOS data characterisation and error estimation
 
 
Titel: GOMOS data characterisation and error estimation
Auteur: J. Tamminen
E. Kyrölä
V. F. Sofieva
M. Laine
J.-L. Bertaux
A. Hauchecorne
F. Dalaudier
D. Fussen
F. Vanhellemont
O. Fanton-d'Andon
G. Barrot
A. Mangin
M. Guirlet
L. Blanot
T. Fehr
L. Saavedra de Miguel
R. Fraisse
Verschenen in: Atmospheric chemistry and physics
Paginering: Jaargang 10 (2010) nr. 19 pagina's 9505-9519
Jaar: 2010
Inhoud: The Global Ozone Monitoring by Occultation of Stars (GOMOS) instrument uses stellar occultation technique for monitoring ozone, other trace gases and aerosols in the stratosphere and mesosphere. The self-calibrating measurement principle of GOMOS together with a relatively simple data retrieval where only minimal use of a priori data is required provides excellent possibilities for long-term monitoring of atmospheric composition. <br><br> GOMOS uses about 180 of the brightest stars as its light source. Depending on the individual spectral characteristics of the stars, the signal-to-noise ratio of GOMOS varies from star to star, resulting also in varying accuracy of retrieved profiles. We present here an overview of the GOMOS data characterisation and error estimation, including modeling errors, for O3, NO2, NO3, and aerosol profiles. The retrieval error (precision) of night-time measurements in the stratosphere is typically 0.5–4% for ozone, about 10–20% for NO2, 20–40% for NO3 and 2–50% for aerosols. Mesospheric O3, up to 100 km, can be measured with 2–10% precision. The main sources of the modeling error are incompletely corrected scintillation, inaccurate aerosol modeling, uncertainties in cross sections of trace gases and in atmospheric temperature. The sampling resolution of GOMOS varies depending on the measurement geometry. In the data inversion a Tikhonov-type regularization with pre-defined target resolution requirement is applied leading to 2–3 km vertical resolution for ozone and 4 km resolution for other trace gases and aerosols.
Uitgever: Copernicus GmbH (provided by DOAJ)
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 9 van 32 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland