Digital Library
Close Browse articles from a journal
 
<< previous    next >>
     Journal description
       All volumes of the corresponding journal
         All issues of the corresponding volume
           All articles of the corresponding issues
                                       Details for article 4 of 11 found articles
 
 
  Comparison of methods for the estimation of measurement uncertainty for an analytical method for sulphonamides
 
 
Title: Comparison of methods for the estimation of measurement uncertainty for an analytical method for sulphonamides
Author: Dabalus Islam, M.
Schweikert Turcu, M.
Cannavan, A.
Appeared in: Food additives and contaminants. Pt. A, Chemistry, analysis, control, exposure & risk assessment
Paging: Volume 25 (2008) nr. 12 pages 1439-1450
Year: 2008-12
Contents: A simple and inexpensive liquid chromatographic method for the determination of seven sulphonamides in animal tissues was validated. The measurement uncertainty of the method was estimated using two approaches: a 'top-down' approach based on in-house validation data, which used either repeatability data or intra-laboratory reproducibility; and a 'bottom-up' approach, which included repeatability data from spiking experiments. The decision limits (CCα) applied in the European Union were calculated for comparison. The bottom-up approach was used to identify critical steps in the analytical procedure, which comprised extraction, concentration, hexane-wash and HPLC-UV analysis. Six replicates of porcine kidney were fortified at the maximum residue limit (100 μg kg-1) at three different stages of the analytical procedure, extraction, evaporation, and final wash/HPLC analysis, to provide repeatability data for each step. The uncertainties of the gravimetric and volumetric measurements were estimated and integrated in the calculation of the total combined uncertainties by the bottom-up approach. Estimates for systematic error components were included in both approaches. Combined uncertainty estimates for the seven compounds using the 'top-down' approach ranged from 7.9 to 12.5% (using reproducibility) and from 5.4 to 9.5% (using repeatability data) and from 5.1 to 9.0% using the bottom-up approach. CCα values ranged from 105.6 to 108.5 μg kg-1. The major contributor to the combined uncertainty for each analyte was identified as the extraction step. Since there was no statistical difference between the uncertainty values obtained by either approach, the analyst would be justified in applying the 'top-down' estimation using method validation data, rather than performing additional experiments to obtain uncertainty data.
Publisher: Taylor & Francis
Source file: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details for article 4 of 11 found articles
 
<< previous    next >>
 
 Koninklijke Bibliotheek - National Library of the Netherlands