Digital Library
Close Browse articles from a journal
 
<< previous   
     Journal description
       All volumes of the corresponding journal
         All issues of the corresponding volume
           All articles of the corresponding issues
                                       Details for article 5 of 5 found articles
 
 
  Use of immunoaffinity columns for clean-up of diarrhetic toxins (okadaic acid and dinophysistoxins) extracts from shellfish prior to their analysis by HPLC/fluorimetry
 
 
Title: Use of immunoaffinity columns for clean-up of diarrhetic toxins (okadaic acid and dinophysistoxins) extracts from shellfish prior to their analysis by HPLC/fluorimetry
Author: Puech, Lilian
Dragacci, Sylviane
Gleizes, Elizabeth
Fremy, Jean-Marc
Appeared in: Food additives and contaminants. Pt. A, Chemistry, analysis, control, exposure & risk assessment
Paging: Volume 16 (1999) nr. 6 pages 239-251
Year: 1999-06-01
Contents: Diarrhetic Shellfish Poisoning (DSP) is a severe gastro-intestinal disease caused by consumption of seafood contaminated by microalgal toxins, mainly okadaic acid (OA) and structurally related toxins, dinophysistoxins (DTXs). Regulatory monitoring is generally based on rodent bioassays which, however, present some technical and ethical disadvantages. The most promising technique of analysis of these toxins involves an HPLC separation with spectrofluorimetric detection after derivatization of the toxins with a fluorescent reagent. The lack of specificity of the extraction procedure (liquid-liquid partition), and the presence of interfering compounds in the matrix, does not allow the determination and the quantification of low amounts of toxins in seafood. In this paper, the authors report the development and the characterization of immunoaffinity columns (IAC), which were elaborated using anti-okadaic acid monoclonal antibodies, for a specific retention of the OA group of toxins. The coupling yield and the stability of these columns were investigated as well as their capacity to remove interfering compounds. Cross-reactivity was observed between the antibodies and the DTX-1 and the DTX-2, allowing the detection of the different toxins in a single analysis. Different spiked (1mugOA/ g) or naturally-contaminated (mussel digestive gland: 2mugOA/g; algae: 165mugOA/g) matrices were tested. The recovery for OA varied from 55 to 95% according to the matrices. The IAC purification was then included as a step of a global [IAC/HPLC/spectrofluorimetric detection] method and the performance of the method was evaluated. Estimations of the linearity and the accuracy (percentages of the presumptive response for OA in the range + 101% to + 114%) were satisfactory in accordance with the method validation criteria.
Publisher: Taylor & Francis
Source file: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details for article 5 of 5 found articles
 
<< previous   
 
 Koninklijke Bibliotheek - National Library of the Netherlands