Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 14 van 28 gevonden artikelen
 
 
  Dual gradient LC method for the determination of pharmaceutical residues in environmental samples using a monolithic silica reversed phase column
 
 
Titel: Dual gradient LC method for the determination of pharmaceutical residues in environmental samples using a monolithic silica reversed phase column
Auteur: Bones, Jonathan
Nesterenko, Pavel
Thomas, Kevin
Paull, Brett
Verschenen in: International journal of environmental analytical chemistry
Paginering: Jaargang 86 (2006) nr. 7 pagina's 487-504
Jaar: 2006-06-15
Inhoud: Detailed below is a simple reversed-phase liquid chromatography (RP-LC) method for the simultaneous separation of up to 21 acidic, basic, and neutral pharmaceuticals using Merck Chromolith Performance RP-C18e monolithic columns with direct ultraviolet (UV) absorption detection. By simultaneously applying a solvent elution gradient program with a mobile phase flow gradient, both a decrease in the overall analysis time and a general increase in peak efficiencies were observed. Mobile phase pH and buffer concentration were optimised using the overall resolution product under applied gradient conditions. Under optimised conditions peak area reproducibility (n = 6) ranged between 0.4 and 9.3%, determined at the method LOQ level. For real sample analysis pharmaceutical residues were extracted using an optimised solid phase extraction (SPE) procedure, utilising Strata-X extraction cartridges, which overall provided the highest relative recovery data in comparison with four other commercially available SPE sorbents (17 out of 20 residues investigated had recoveries over 70%). Complete method precision, including all sample pre-treatment and LC analysis for six spiked river water samples at the 1 and 2 µg L-1 level was between 10 and 29%. Using 1 L volumes of 1 µg L-1 spiked estuarine water samples, the majority of detection limits were found to be in the 10-50 ng L-1 range.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 14 van 28 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland