Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 3 van 20 gevonden artikelen
 
 
  A novel equilibrium extraction technique employing hollow fibre liquid phase microextraction for trace enrichment of freely dissolved organophosphorus pesticides in environmental waters
 
 
Titel: A novel equilibrium extraction technique employing hollow fibre liquid phase microextraction for trace enrichment of freely dissolved organophosphorus pesticides in environmental waters
Auteur: Berhanu, Tarekegn
Megersa, Negussie
Solomon, Theodros
Jonsson, Jan Åke
Verschenen in: International journal of environmental analytical chemistry
Paginering: Jaargang 88 (2008) nr. 13 pagina's 933-945
Jaar: 2008-11
Inhoud: A new design of equilibrium hollow fibre liquid phase microextraction (HF-LPME) was developed for the determination of three freely dissolved organophosphorus pesticides (OPPs), i.e. diazinon (O,O-diethyl-O-2-isopropyl-4-methyl-6-pyrimidyl thiophosphate), chlorpyrifos (O,O-diethyl-O-[3,5,6-trichloro-2-pyridyl] phosphorothioate), and fenthion (O,O-dimethyl-O-4-methylthio-m-tolyl phosphorothioate) as model compounds. In this new design a 1.2-1.4 cm length of a hollow fibre (HF), inserted to the end of 20 cm copper wire and impregnated with organic solvent, was used to extract the freely dissolved concentration of OPPs in various water samples. The limits of detection (LOD) in reagent water using gas chromatography-mass spectrometry in the selected ion monitoring (SIM) mode was in the range of 15-80 ng L-1. The relative standard deviations of the analysis (inter- and intra-day) were 8.7-30%. The method was applied to the extraction of spiked lake and ground water samples. The ground water sample was spiked at 0.1 and 0.2 µg L-1 concentrations of the analytes under study and the average extraction efficiency at the two concentrations was below 1% showing the non-depletive nature of the extraction, meaning that the freely dissolved concentrations are measured as opposed to total concentrations. Good linearity was obtained for all of the analytes in both reagent water and lake water samples with correlation coefficients, R2, ranging from 0.991 to 0.996, in the concentration ranges of 25-400 ng L-1. The method was found to be very simple and inexpensive, with the possibility of running hundreds of samples in parallel with very minimal expenses for the determination of freely dissolved OPPs.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 3 van 20 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland