Digital Library
Close Browse articles from a journal
 
<< previous   
     Journal description
       All volumes of the corresponding journal
         All issues of the corresponding volume
           All articles of the corresponding issues
                                       Details for article 14 of 14 found articles
 
 
 
 
 
Title:
Author:
Appeared in: Analytical letters
Paging: Volume 40 (2007) nr. 16 pages 3070-3079
Year: 2007-01
Contents: A fast, reliable, and low cost biamperometric flow-injection method, with an error of 1.3% and an analytical throughput of 55 samples h-1, for determination of tetracycline hydrochloride in pharmaceuticals capsules is proposed. The analytical curve was linear (r=0.998) in the range 10 to 50 mg l-1 using Fe(CN)63- and NaOH solutions as reagent and carrier stream/supporting electrolyte, respectively. A relative standard deviation of 1.6% (10 sequential injections of 30.0 mg l-1) was verified with detection and quantification limits of 0.6 and 3.4 mg l-1, respectively.
Publisher: Taylor & Francis
Source file: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details for article 14 of 14 found articles
 
<< previous   
 
 Koninklijke Bibliotheek - National Library of the Netherlands