Digital Library
Close Browse articles from a journal
 
   next >>
     Journal description
       All volumes of the corresponding journal
         All issues of the corresponding volume
           All articles of the corresponding issues
                                       Details for article 1 of 8 found articles
 
 
  Design, calibration and geological application of the first operational Australian laser ablation sulphur isotope microprobe
 
 
Title: Design, calibration and geological application of the first operational Australian laser ablation sulphur isotope microprobe
Author: Huston, D. L.
Power, M.
Gemmell, J. B.
Large, R. R.
Appeared in: Australian journal of earth sciences
Paging: Volume 42 (1995) nr. 6 pages 549-555
Year: 1995-12
Contents: This contribution describes the setup and operating procedures of the first operational laser ablation microprobe for stable (sulphur) isotope analysis in Australia as well as some brief geological applications. A significant feature on this laser ablation microprobe is automated gas purification and analysis; operator control is only required to locate and ablate sample targets. As with other laboratories, samples were ablated in an oxygen atmosphere, producing a SO2/O2 gas mixture. SO2 was separated from this mixture by either of two techniques. In the first technique, SO2 was condensed into a liquid N2 trap by cryogenic pumping, and O2 was pumped away. This resulted in the collection of 60-70% of the produced SO2. In the second technique, SO2 was condensed into a liquid N2 trap as the SO2/O2 mixture was slowly bled away. This technique collected 90-95% of the SO2, with a small fractionation of 0.16%. Laser ablation and SO2 collection via the second technique required a mineral dependent, additive correction of 2.85-5.75% to convert raw δ34S values to δ34SCDT. These correction factors are mineral and laboratory dependent, and from our data, seem to be dependent on the quality of polish of the ablated sample. Precision (1σ) of laser ablation sulphur isotope analysis is 0.4-0.5%o for 150 μm ablation craters. Preliminary results of studies on samples from the Broken Hill, Hellyer and active sea floor Pacmanus deposits indicate that laser ablation microprobe analysis can show subtle variations in δ34S not apparent using either conventional or SHRIMP analysis. Laser ablation analysis indicates a larger range, but similar mean values, to conventional analysis on the same samples.
Publisher: Taylor & Francis
Source file: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details for article 1 of 8 found articles
 
   next >>
 
 Koninklijke Bibliotheek - National Library of the Netherlands