Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 7 van 10 gevonden artikelen
 
 
  Establishing an optimal trajectory for calcaneotibial K-wire fixation in emergent treatment of unstable ankle fractures
 
 
Titel: Establishing an optimal trajectory for calcaneotibial K-wire fixation in emergent treatment of unstable ankle fractures
Auteur: Schröder, M.
Stüber, V.
Walendzik, E.
O'Loughlin, P.F.
Zapf, A.
Krettek, C.
Gaulke, R.
Verschenen in: Technology & health care
Paginering: Jaargang 23 (2014) nr. 2 pagina's 215-221
Jaar: 2014-12-10
Inhoud: OBJECTIVE: In unstable ankle fractures the associated soft tissue damage can be a therapeutic challenge. The aim of this study was to optimize planning of minimally invasive stabilization of ankle fractures by calcaneotibial transfixation, which is a demanding technique due to the complex hind foot anatomy. METHODS: In a retrospective radiographic analysis the angles and dimensions of a safe drill tunnel for calcaneotibial K-wire insertion were defined on standard radiographs of the ankle joint. 165 lateral weight-bearing radiographs (77 right; 88 left) and 147 (80 right; 67 left) mortise views of 186 (90 right; 96 left) uninjured feet from 123 patients (74 women (114 feet); 49 men (72 feet)) were included in this study. The average patient age was 49 (range, 13–85) years. Inter- and intra-observer reliability was evaluated on 20 randomized radiographs that were analyzed in a default set, three times, by two different examiners on three different days. RESULTS: In the lateral view the drilling tunnel was orientated at 59.4° to the plantar plane with a maximum proximal variance of 7.1 image-mm. Distal variance cannot be tolerated since an ankle joint injury would ensue. In the mortise view the drill tunnel was directed with a mean angle of 18.4° to the distal tibial articular surface. At most a mean of 11° fibular- and 13.4° tibial- expansion can be tolerated. Intra- and inter-observer reliability was higher for the angles than for the drill corridors. CONCLUSION: The three-dimensional (3D) orientation for safe K-wire placement for calcaneotibial transfixation should adhere to the drill tunnels established in this study.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 7 van 10 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland