Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 8 van 12 gevonden artikelen
 
 
  Is the Kinect system suitable for evaluation of the hip joint range of motion and as a screening tool for femoroacetabular impingement (FAI)?
 
 
Titel: Is the Kinect system suitable for evaluation of the hip joint range of motion and as a screening tool for femoroacetabular impingement (FAI)?
Auteur: Lahner, Matthias
Mußhoff, Dennis
von Schulze Pellengahr, Christoph
Willburger, Roland
Hagen, Marco
Ficklscherer, Andreas
von Engelhardt, Lars Victor
Ackermann, Ole
Lahner, Nina
Vetter, Gregor
Verschenen in: Technology & health care
Paginering: Jaargang 23 (2014) nr. 1 pagina's 75-81
Jaar: 2014-11-11
Inhoud: BACKGROUND: In the clinical evaluation of femoroacetabular impingement (FAI), there is a lack of quantitative, reliable and informative assessment methods for the overall functional capability of an individual. OBJECTIVE: We compared clinical and radiological measurements of the hip joint with a new methodology based on the concept of 3-dimensional reachable workspace using Microsoft Kinect. METHODS: We assessed the correlation between the alpha angle of Nötzli on full-length radiographs and the clinical internal rotation. We evaluated the accuracy of joint positions and angles of the hip between the Kinect system and clinical examination including range of motion (ROM). RESULTS: The results of our clinical trial with 24 study participants showed a significant difference between normal internal rotation (> 21°) and reduced internal rotation (⩽ 21°) in comparison to the radiological alpha angle of Nötzli (P=0.026). The acquired reachable Kinect data demonstrated a moderate agreement between the Kinect and clinical examination (correlation coefficients between 0.230 and 0.375). CONCLUSIONS: The findings suggest that a higher grade alpha angle of Nötzli accompanies reduced clinical internal rotation. The Kinect system provides reliable results of hip ROM. However, further test series must be performed for the application of Kinect in the clinical evaluation of FAI.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 8 van 12 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland