Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 13 van 26 gevonden artikelen
 
 
  Finite element analysis of a bone-implant system with the proximal femur nail
 
 
Titel: Finite element analysis of a bone-implant system with the proximal femur nail
Auteur: Helwig, P.
Faust, G.
Hindenlang, U.
Kröplin, B.
Eingartner, C.
Verschenen in: Technology & health care
Paginering: Jaargang 14 (2006) nr. 4-5 pagina's 411-419
Jaar: 2006-10-20
Inhoud: Static analysis with finite element of a realistic femur nail bone-implant system in a typical proximal femoral fracture under physiological load bearing situations provides results for stress, displacement and strain. The question to be answered is, if simulation with the finite element analysis is able to explain biomechanically clinical observed patterns of failure. Surface-Reconstruction with CT database of a proximal femur and reconstruction with CT based density data was done. Next steps were to unite the bone structure with the Proximal Femoral Nail and to model two relevant fractures (31-A2.2 and A2.3 according AO). After modelling of geometry, isotropic material behaviour and load application numeric calculation of the femur-nail system with FE-software was performed. FE simulation mainly shows an axial dislocation of the femoral head screw with nearly no dislocation of the antirotation screw. This so-called z-effect therefore means: (1) Tilting of the proximal main fragment around the sagittal axis between the screws and (2) relative movement of both screws in the frontal plane. Relative movement of the two screws against each other could be the reason for implant failure, the so called cut out. Furthermore simulation shows different gliding of the screws explaining the so called z-telescoping. The analyzed stress patterns have to be relativized, because isotropic material behaviour of cancellous bone was assumed. Further examinations for this issue are necessary.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 13 van 26 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland