Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 3 van 8 gevonden artikelen
 
 
  Application of the Volatility-TDMA Technique to Determine the Number Size Distribution and Mass Concentration of Less Volatile Particles
 
 
Titel: Application of the Volatility-TDMA Technique to Determine the Number Size Distribution and Mass Concentration of Less Volatile Particles
Auteur: Frey, Anna
Rose, Diana
Wehner, Birgit
Muller, Thomas
Cheng, Yafang
Wiedensohler, Alfred
Virkkula, Aki
Verschenen in: Aerosol science and technology
Paginering: Jaargang 42 (2008) nr. 10 pagina's 817-828
Jaar: 2008-10
Inhoud: A Volatility-Tandem-Differential-Mobility-Analyzer (VTDMA) and a Differential Mobility Particle Sizer (DMPS) were used to determine the number and mass concentration of externally mixed aerosol particles in urban background air. In the VTDMA the less-volatile (LV) particle fraction was measured at 300°C for particles in the size range 20-250 nm. The LV particle fraction was converted to the number concentration of LV particles (NLV) and the mass concentration (MLV). MLV was compared with the mass concentration of black carbon (MBC) measured by a Multi-Angle Absorption Photometer (MAAP). The DMPS and VTDMA data were used for calculating scattering and absorption coefficients (σSP and σAP) with a Mie model and compared with σSP and σAP measured with a TSI nephelometer and the MAAP. The model was run by assuming external and internal mixing of absorbing and scattering aerosol. The best fit of measured and modeled σSP and σAP was sought by varying the refractive index. During periods dominated by local emissions LV particle fraction 〈ϕLV 〉 was high ( >0.2). In these cases, the MLV and the modeled σAP assuming external mixing agreed well with the measured MBC and σAP, respectively. For the long-range transported aerosol 〈ϕLV 〉 was small ( <0.1) and MBC was higher than MLV. For the whole period the average (± std) refractive index was 1.55 (± 0.09) - 0.04 (±0.02)i when internal mixing was assumed. When 〈ϕLV 〉 was >0.2 the average refractive index of LV particles was 1.96 - 0.8 (±0.18)i when σAP was modeled assuming external mixing.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 3 van 8 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland