Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige   
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 10 van 10 gevonden artikelen
 
 
  Intercomparison of Real Time Ammonium Measurements at Urban and Rural Locations in New York
 
 
Titel: Intercomparison of Real Time Ammonium Measurements at Urban and Rural Locations in New York
Auteur: Bae, Min-Suk
Demerjian, Kenneth L.
Schwab, James J.
Weimer, Silke
Hou, Jian
Zhou, Xianliang
Rhoads, Kevin
Orsini, Doug
Verschenen in: Aerosol science and technology
Paginering: Jaargang 41 (2007) nr. 3 pagina's 329-341
Jaar: 2007-03
Inhoud: A formal intercomparison of fine particle ammonium was conducted involving three real-time semi-continuous measurement systems and an integrated filter measurement. The three semi-continuous sampling techniques are 1) the Particle-into-Liquid Sampler—Ion Chromatography (PILS-IC), 2) the Quadropole-Aerosol Mass Spectrometer (Q-AMS), which is able to identify the particle size distribution and chemical composition alternately, and 3) the Wet Scrubbing-LOng Path Absorption Photometer (WS-LOPAP) that is based on aqueous scrubbing through a glass frit impactor with analysis by long path absorption spectrophotometry. The 24 hour co-located filter based measurements are from EPA Speciation Trends Network (STN) protocol samplers with 1-in-3 day sampling. The measurements were made at the rural site of Pinnacle State Park (PSP) in upstate New York from July 18 through August 8 in 2004 and the urban site of Queens College (QC) in New York City from January 9 through February 6 in 2004. Intercomparison of hourly averaged particulate ammonium measurements from the three semi-continuous instruments shows correlations with recoveries (forced zero intercept) between 0.71 and 1.04 with all R2 values above 0.82 at PSP. The comparable recovery at QC is 1.00 between Q-AMS and PILS-IC with R2 of 0.77. While there is an overall agreement among the methods, some systematic and episodic differences are also noted. Sample handling, collection efficiency and seasonal differences are considered as possible reasons for the observed differences.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 10 van 10 gevonden artikelen
 
<< vorige   
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland