Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 7 van 8 gevonden artikelen
 
 
  Modeling and Characterization of a Particle-into-Liquid Sampler (PILS)
 
 
Titel: Modeling and Characterization of a Particle-into-Liquid Sampler (PILS)
Auteur: Sorooshian, Armin
Brechtel, Fred J.
Weber, Rodney J.
Corless, Andrew
Flagan, Richard C.
Seinfeld, John H.
Verschenen in: Aerosol science and technology
Paginering: Jaargang 40 (2006) nr. 6 pagina's 396-409
Jaar: 2006-07-01
Inhoud: A modified particle-into-liquid sampler (PILS), based on the original design of Weber et al. (2001), is presented. The principal modification in this design is that collected liquid sample is delivered to vials held on a rotating carousel as opposed to an on-line analytical detector. A model is developed to predict aerosol mass concentrations measured by a PILS based on operating parameters and characteristics of the sampled aerosol. A backward model predicts the concentrations of the sampled aerosol based on operating parameters and concentrations measured by the PILS. Both models, which consider plumbing transmission efficiencies, droplet growth, mixing effects, and volatilization losses, predict mass concentrations that are consistent with laboratory tests for step changes in concentration. The average collection efficiency for species (Na+, K+, SO42-, Cl-, NO3-) from a variety of aerosols compared to simultaneous measurements with a differential mobility analyzer (DMA) exceeded 96% except for NH4+ (88%); NH4+ is theoretically shown to be the most vulnerable to volatilization, followed by Cl- and then NO3-, with greater losses caused by increasing droplet pH and temperature. The characterization tests highlight the importance of reducing NH4+ volatilization by keeping a stable tip temperature of 100°C at the point where steam and ambient air mix in the condensation chamber. Maintaining a stable tip temperature also avoids fluctuations in supersaturations that lead to increased deposition losses of larger droplets. Sample data from the 2004 International Consortium for Atmospheric Research on Transport and Transformation (ICARTT) field campaign are presented.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 7 van 8 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland