Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 5 van 11 gevonden artikelen
 
 
  Field Validation of the New Miniature Versatile Aerosol Concentration Enrichment System (mVACES)
 
 
Titel: Field Validation of the New Miniature Versatile Aerosol Concentration Enrichment System (mVACES)
Auteur: Ning, Zhi
Moore, Katharine F.
Polidori, Andrea
Sioutas, Constantinos
Verschenen in: Aerosol science and technology
Paginering: Jaargang 40 (2006) nr. 12 pagina's 1098-1110
Jaar: 2006-12
Inhoud: Recently a new compact aerosol concentration enrichment system was developed at the University of Southern California, specifically intended to provide particle-laden air at flow rates and pressures suitable for interfacing with on-line continuous aerosol instrumentation for chemical analysis such as mass spectrometers. The re-design and engineering of the miniature Versatile Aerosol Concentration Enrichment System (mVACES) and primarily laboratory-based validation of the individual components and overall system has been previously reported (Geller et al. 2005). From September to December 2005, a field performance validation study of the mVACES was conducted in Los Angeles, California at a mixed urban site influenced by both freeway traffic and construction. A variety of continuous and semi-continuous physical and chemical composition measurements were performed to assess the performance of the mVACES compared to accepted methods for validation. Near-ideal performance for aerosol concentration enhancement by the mVACES was observed for mass and number distribution with minimal evidence for distortion of the size distribution. Similarly, near-ideal concentration enhancement factors were observed for both inorganic and organic species suggesting that the mVACES works equally well across the range of externally mixed urban aerosol. The data suggest that aerosol concentration enhancements up to an ideal factor of 20 in a delivered flow on the order of 1.5 liters min-1 are readily achievable in an urban environment for the ambient conditions studied.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 5 van 11 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland