Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 15 van 19 gevonden artikelen
 
 
  Measurement of Both Nonvolatile and Semi-Volatile Fractions of Fine Particulate Matter in Fresno, CA
 
 
Titel: Measurement of Both Nonvolatile and Semi-Volatile Fractions of Fine Particulate Matter in Fresno, CA
Auteur: Grover, Brett D.
Eatough, Norman L.
Eatough, Delbert J.
Chow, Judith C.
Watson, John G.
Ambs, Jeffrey L.
Meyer, Michael B.
Hopke, Philip K.
Al-Horr, Rida
Later, Douglas W.
Wilson, William E.
Verschenen in: Aerosol science and technology
Paginering: Jaargang 40 (2006) nr. 10 pagina's 811-826
Jaar: 2006-10-01
Inhoud: An intensive sampling campaign was performed in Fresno, CA during December 2003 measuring fine particulate matter including both the semi-volatile and nonvolatile fractions of the aerosol. Both the newly developed R&P FDMS Monitor and a PC-BOSS have been shown to measure total PM2.5 concentrations including semi-volatile nitrate and organic material. Good agreement was observed between the PC-BOSS and the R&P FDMS Monitor in this study with linear regression analysis resulting in a zero-intercept slope of 1.00 ± 0.02 and an R2 = 0.93. Several real-time measuring systems including the R&P Differential TEOM, the Met One BAMS, and a GRIMM Monitor were also employed and comparisons of total PM2.5 mass were made with the R&P FDMS Monitor. Agreement among these various monitors was generally good. However, differences were sometimes seen. Reasons for observed differences in the real-time mass measurement systems are explained by the composition and complexity of the measured aerosol, most importantly the composition of semi-volatile material. A newly automated ion chromatographic system developed by Dionex was also field tested and compared to both R&P 8400N Nitrate and integrated PC-BOSS inorganic species measurements. Sulfate and nitrate determined by the Dionex and PC-BOSS systems agreed. However, nitrate measured by the 8400N was low during fog events compared to the other two systems.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 15 van 19 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland