  Performance Evaluation of a Recently Developed Water-Based Condensation Particle Counter
 
 
Titel: Performance Evaluation of a Recently Developed Water-Based Condensation Particle Counter
Auteur: Biswas, Subhasis
Fine, Philip
Geller, Michael
Hering, Susanne
Sioutas, Constantinos
Verschenen in: Aerosol science and technology
Paginering: Jaargang 39 (2005) nr. 5 pagina's 419-427
Jaar: 2005-01
Inhoud: This study provides an intercomparison of the performance of a newly developed water-based condensation particle counter (W-CPC) and a more widely used butanol-based CPC (TSI 3022A). Four test aerosols (ammonium nitrate, ammonium sulfate, adipic acid, and glutaric acid) were generated and tested in the laboratory before the instruments were deployed at four field locations (USC/downtown LA, I-710 Freeway, Pacific coast, and Los Angeles International Airport). Both instruments sampled the same incoming aerosol. Selected experiments utilized a differential mobility analyzer to select a particle size upstream of the CPCs. Evaluation of performance was based on the response of the instruments to varying particle composition, concentrations, and size. The results indicated good correlation between the two CPCs, with R2 values ranging from 0.74-0.99. Good agreement was found between the two instruments for particle concentrations between 0 and 40,000 particles/cm3, with W-CPC/TSI 3022A ratios between 0.8 and 1.2. Due to differences in the photometric mode calibration of these instruments, the ratio drops to 0.6-0.8 between 40,000-100,000 particles/cm3. However, the ratio rises again for lab aerosols above 100,000 particles/cm3 to 1.0-1.1. Results of this evaluation show that the W-CPC is a reliable particle- counting technology for particle concentrations encountered downstream of a DMA as well as in some ambient environments (< 40,000 particles/cm3).
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 11 van 11 gevonden artikelen
 
<< vorige   
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland