  Elemental Analysis of Sub-Hourly Ambient Aerosol Collections
 
 
Titel: Elemental Analysis of Sub-Hourly Ambient Aerosol Collections
Auteur: Kidwell, Christopher B.
Ondov, John M.
Verschenen in: Aerosol science and technology
Paginering: Jaargang 38 (2004) nr. 3 pagina's 205-218
Jaar: 2004-03
Inhoud: Simultaneous multielement graphite furnace atomic absorption spectrometry was used to determine Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Se, and Zn in ambient air sampled at 170 L·min-1 for 30 min and collected as a slurry after dynamic preconcentration. In PM20 samples collected at College Park, MD, results were > 2σ above system blank in > 95% of samples for Al, Cd, Cu, Cr, Fe, Mn, Pb, and Zn, and > 2σ above system blank in > 80% of samples for As, Ni, and Se. Analyses of slurries of NIST SRM 1648, Urban Particulate Matter, were typically within 10% of expected values for all elements except Al, Cr, and Fe, elements for which deviations were mostly due to difficulties in transferring large particles. This problem will be reduced for urban fine particulate matter samples (PM2.5). Trends in the concentrations of elemental source markers were readily correlated with wind direction and other meteorological factors to identify the influences of local industrial emissions, including motor vehicle traffic, coal- and oil-fired power plants, and municipal incinerators. Factor analysis was applied to the 88-sample data set to extract 7 factors: urban dust, meteorological factors, incinerators, coal-fired power plants, Tour Bus emission, unknown As source, and oil-fired power plants. Factor analysis was also applied to an 18-sample data set representing 2.5 h averages of the 30 min data to simulate the effect of longer sample collection times. Only 6 factors were extracted from this data set, which shows that increased temporal resolution enhances the power of factor analysis to resolve sources. These results indicate that a wealth of detailed information is revealed at this level of temporal resolution.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 