Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 10 van 16 gevonden artikelen
 
 
  High-Volume Diffusion Denuder Sampler for the Routine Monitoring of Fine Particulate Matter: I. Design and Optimization of the PC-BOSS
 
 
Titel: High-Volume Diffusion Denuder Sampler for the Routine Monitoring of Fine Particulate Matter: I. Design and Optimization of the PC-BOSS
Auteur: Ding, Yiming
Pang, Yanbo
Eatough, Delbert J.
Verschenen in: Aerosol science and technology
Paginering: Jaargang 36 (2002) nr. 4 pagina's 369-382
Jaar: 2002-01
Inhoud: Fine particulate mass will frequently be significantly underestimated in urban environments using current EPA federal reference method (FRM) single filter samplers because of loss of semivolatile organic material and nitrate from the particles during sampling. Previously described diffusion denuder samplers, such as the Brigham Young University organic sampling system (BOSS) and BIG BOSS, eliminate both positive and negative sampling artifacts by removing the gas-phase material before fine particulate mass is collected on a quartz filter and a sequential sorbent filter or bed. However, these samplers are not amenable to routine field use because they require multiple systems to accurately account for the efficiency of the denuder for each sample. The denuder efficiency is substantially improved by combining a conventional 2.5 μm cutpoint inlet and a low cutpoint virtual impactor particle concentrator to provide concentrated fine particles (0.1-2.5 μm) to a BOSS diffusion denuder sampling system (PC-BOSS). The performance of both the particle concentrator and the diffusion denuder in the PC-BOSS has been evaluated. Under optimized conditions, the minor to total flow ratio for the concentrator is 25% and the concentrator efficiency is 70-90% for sulfate and 60-85% for soot, depending on the particle size distribution of these species. The particle loss in the concentrator is about 6%. The particle loss in the denuder system is negligible. At the recommended optimum minor flow (concentrated particles, 25% of the total flow), most of the gas-phase material is discarded by the particle concentrator before the concentrated fine particles enter the diffusion denuder. At an optimized inlet flow of 150 L/min with a flow through the denuder of 38 L/min, the overall efficiency of the PC-BOSS for the removal of gas-phase organic material, SO 2 , and HNO 3 is over 99%. Therefore independent determination of the denuder breakthrough can be eliminated in the PC-BOSS.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 10 van 16 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland