Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 2 van 9 gevonden artikelen
 
 
  Computational Fluid Dynamic Predictions and Experimental Results for Particle Deposition in an Airway Model
 
 
Titel: Computational Fluid Dynamic Predictions and Experimental Results for Particle Deposition in an Airway Model
Auteur: Oldham, Michael J.
Verschenen in: Aerosol science and technology
Paginering: Jaargang 32 (2000) nr. 1 pagina's 61-71
Jaar: 2000-01-01
Inhoud: An area identified as having a high priority by the National Research Council (NRC 1998) relating to health effects of exposure to urban particulate matter is the investigation of particle deposition patterns in potentially-susceptible subpopulations. A key task for risk assessment is development and refinement of mathematical models that predict local deposition patterns of inhaled particles in airways. Recently, computational fluid dynamic modeling (CFD) has provided the ability to predict local airflows and particle deposition patterns in various structures of the human respiratory tract. Although CFD results generally agree with available data from human studies, there is a need for experimental particle deposition investigations that provide more detailed comparisons with computed local patterns of particle deposition. Idealized 3-generation hollow tracheo-bronchial models based on the Weibel symmetric morphometry for airway lengths and diameters (generations 3-5) were constructed with physiologically-realistic bifurcations. Monodisperse fluorescent polystyrene latex particles (1 and 10 mu m aerodynamic diameter) were deposited in these models at a steady inspiratory flow of 7.5 L /min (equivalent to heavy exertion with a tracheal flow of 60 L /min). The models were opened and the locations of deposited particles were mapped using fluorescence microscopy. The particle deposition predictions using CFD for 10 mu m particles correlated well with those found experimentally. CFD predictions were not available for the 1 mu m diameter case, but the experimental results for such particles are presented.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 2 van 9 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland