  Response of Particle Measuring Systems Airborne ASASP and PCASP to NaCl and Latex Particles
 
 
Titel: Response of Particle Measuring Systems Airborne ASASP and PCASP to NaCl and Latex Particles
Auteur: Liu, P. S. K.
Leaitch, W. R.
Strapp, J. W.
Wasey, M. A.
Verschenen in: Aerosol science and technology
Paginering: Jaargang 16 (1992) nr. 2 pagina's 83-95
Jaar: 1992
Inhoud: The response of a Particle Measuring Systems, Inc. (PMS) airborne Passive Cavity Aerosol Spectrometer Probe (PCASP)-100X and a PMS airborne Active Scattering Aerosol Spectrometer Probe (ASASP)-100X to nearly monodisperse aerosols of NaCl and polystyrene latex spheres in the size range 0.074-1.07 μm diameter (± 5%) are examined. Particles < 0.34 μm are size classified by electrical mobility using a Thermo System Inc. Electrostatic Classifier. The particles are also sized with the aid of a scanning electron microscope. Three equivalent diameters for the near cubic NaCl particles are considered: average of length and breadth, and cross section equivalent and volume equivalent diameters. For the linear diameter, the probes' response to latex and NaCl particles is quite similar. However, the use of cross section and volume equivalent diameter leads NaCl to be sized significantly less than the latex spheres consistent with reported differences between spherical (i.e., latex) and cubical geometry (i.e., NaCl). Using the linear diameter the lower detection limit of the ASASP-100X is found to be 0.175 μm ±5%, not 0.120 μm as given by the manufacturer. The lower detection limit of the PCASP-100X is found to be 0.125 μm ±5%, compared with the value of 0.10 μm suggested by PMS. In spite of this discrepancy the PCASP still represents a significant advancement for the airborne measurement of aerosol size distributions. Size distributions measured simultaneously with the two probes from an aircraft agreed more favorably with the new calibrations than with those of the manufacturer.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 5 van 5 gevonden artikelen
 
<< vorige   
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland