Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 4 van 21 gevonden artikelen
 
 
  Atmospheric Gas and Particle Phase Concentrations of Polychlorinated Biphenyls (PCBs) in a Suburban Site of Bursa, Turkey
 
 
Titel: Atmospheric Gas and Particle Phase Concentrations of Polychlorinated Biphenyls (PCBs) in a Suburban Site of Bursa, Turkey
Auteur: Cindoruk, S. Sıddık
Tasdemir, Yucel
Verschenen in: Environmental forensics
Paginering: Jaargang 9 (2008) nr. 2-3 pagina's 153-165
Jaar: 2008-04
Inhoud: Ambient air samples were collected between July 2004 and May 2005 with a high-volume air sampler (HVAS) in order to investigate the gas and particle concentration levels of polychlorinated biphenyls (PCBs) in a suburban site (the Uludag University Campus) in Bursa, Turkey. Average particle and gas-phase PCB concentrations (average ± standard deviation) were 85.8 ± 127.8 pg m-3 and 328.1 ± 284.2 pg m-3, respectively. Total (gas+particle) PCB concentrations were higher in the warmer periods, while an opposite case was observed for the colder periods. The application of the Clausius-Clapeyron equation representing the relationship between gas-phase PCB concentrations and air temperature yielded a significant correlation. Moreover, the relationships between PCB congeners and meteorological variables were investigated. Based on meteorological variables and back trajectory results, evaporation and atmospheric transport were assumed to be the major sources of PCBs in the sampling site. PCBs are partitioned between gas and particle phases, and this fate was examined using different available approaches such as logKP-logPLo, logKP-logKOA, and Junge-Pankow model. Shallow slopes between -0.18 and -0.48 were obtained from the logKP-logPLo plot, while the slope of logKP-logKOA ranged from 0.2 to 0.42. PLo and KOA values obtained from the literature were both considered good descriptors for determination of KP experimental partitioning coefficient in the site. Correlations were significant at p < 0.01 for all approaches.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 4 van 21 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland