Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 10 van 18 gevonden artikelen
 
 
  Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion
 
 
Titel: Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion
Auteur: Bedekar, Nilima
Suryawanshi, Mayuri
Rairikar, Savita
Sancheti, Parag
Shyam, Ashok
Verschenen in: Journal of back and musculoskeletal rehabilitation
Paginering: Jaargang 27 (2013) nr. 2 pagina's 161-166
Jaar: 2013-09-12
Inhoud: BACKGROUND: Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). OBJECTIVES: To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. METHOD: iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. RESULTS: Intra-rater reliability using ICC was r=0.920 and inter-rater r=0.812 at CI 95%. Validity r=0.95. CONCLUSION: Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 10 van 18 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland