  Gelatin sealing sheet for arterial hemostasis and anti-adhesion in vascular surgery: A dog model study
 
 
Titel: Gelatin sealing sheet for arterial hemostasis and anti-adhesion in vascular surgery: A dog model study
Auteur: Hu, Yinghao
Yamashita, Keigo
Tabayashi, Nobuoki
Abe, Takehisa
Hayata, Yoshihiro
Hirose, Tomoaki
Hiraga, Shun
Tojo, Takashi
Suzuki, Shuko
Ikada, Yoshito
Taniguchi, Shigeki
Verschenen in: Bio-medical materials and engineering
Paginering: Jaargang 25 (2015) nr. 2 pagina's 157-168
Jaar: 2015-03-26
Inhoud: BACKGROUND: The bilayer gelatin sealing sheet was developed as a safe, effective, easy-to-handle and low-cost hemostatic agent. OBJECTIVE: To examine the feasibility of gelatin sealing sheets using a canine arterial hemorrhage model. METHODS: In vivo degradation of gelatin sealing sheets was examined by implanting subcutaneously in rats. For the hemostatic and anti-adhesion efficacy investigations, femoral arteries of dogs were pricked with syringe needle to make a small hole and a gelatin (i.e. experimental group) or fibrin glue sealing sheet (i.e. control group) was applied on the hole to stop bleeding (n=8). After discontinuation of the bleeding, the skin incisions were closed and re-examined 4 weeks postoperatively. RESULTS: From the degradation study, 4 h thermally treated gelatin sheet which degraded within 3 weeks in vivo was chosen for the further hemostatic study. In all cases of gelatin and fibrin glue sealing sheets, bleeding from the needle hole on canine femoral arteries was effectively stopped. Postoperative adhesions and inflammation at the site in the experimental group were significantly less than those in the control group (P<0.01 for adhesion scores). CONCLUSIONS: The gelatin sealing sheet was found to be as effective as the fibrin glue sealing sheet as a surgical hemostatic agent, and more effective in preventing postoperative adhesions.