Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 6 van 8 gevonden artikelen
 
 
  The effect of interspinous ligament integrity on adjacent segment instability after lumbar instrumentation and laminectomy - An experimental study in porcine model
 
 
Titel: The effect of interspinous ligament integrity on adjacent segment instability after lumbar instrumentation and laminectomy - An experimental study in porcine model
Auteur: Chen, Lih-Huei
Lai, Po-Liang
Tai, Ching-Lung
Niu, Chi-Chien
Fu, Tsai-Sheng
Chen, Wen-Jer
Verschenen in: Bio-medical materials and engineering
Paginering: Jaargang 16 (2006) nr. 4 pagina's 261-267
Jaar: 2006-08-23
Inhoud: Eight fresh porcine lumbar spines received a posterior instrumentation at L4-L5 using pedicle screw-rod system. Each specimen was tested utilizing laminectomies of varying extent. Group A (Integrity) preserved the spinous process and interspinous ligament; Group B (Partial laminectomy) removed the inferior portion of L4 spinous process and preserved the interspinous ligament of L3-L4; Group C (Complete laminectomy) removed the entire L4 spinous process. Hydraulic testing machine was used to generate an increasing moment up to 8400 N mm in flexion and extension. The intervertebral displacement on the superior adjacent disc between L3-L4 was measured using an extensometer. Under extension, no significant difference in the intervertebral displacement was observed among three different models of laminectomy. However, under flexion, the intervertebral displacement on adjacent disc with complete laminectomy was statistically larger than those of integrity and partial laminectomies (P=0.000976 and P=0.0363, respectively). No difference was found between integrity and partial laminectomy groups (P>0.05). This study implies that an instrumented spine with integrity of posterior complex is less likely to develop adjacent instability than a spine with destruction of the anchoring point for supraspinous ligament.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 6 van 8 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland