Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 2 van 8 gevonden artikelen
 
 
  Effect of type of polymerization on different properties of dental composites
 
 
Titel: Effect of type of polymerization on different properties of dental composites
Auteur: N. Kaprielian
C. Lagneau
N. Zydowicz
M. Lissac
B. Grosgogeat
Verschenen in: Bio-medical materials and engineering
Paginering: Jaargang 15 (2005) nr. 6 pagina's 483-493
Jaar: 2005-11-22
Inhoud: The aim of this study is to assess the influence of plasma lamps on the properties of the composites compared to the influence of conventional polymerization. Vickers hardness tests, three-point bending tests, and measurement of the shrinkage marginal gap by scanning electron microscopy were carried out on three resin composites (Tetric® Ceram, Z-100™ and Inten-S®) irradiated with to lamps (Flipo® plasma and Astralis® 7 halogen lamps). With a 3-second exposure, the results of Vickers hardness and resistance to flexion (excepting values for Z-100™) were lower for the composites cured by the Flipo® plasma lamp, than after 40-second curing by the conventional halogen lamp (Astralis® 7), notably at a depth of 3 mm. With a 5-second exposure the results of Vickers hardness and resistance to flexion obtained using the plasma lamp approached those obtained by using the halogen lamp. Whatever the polymerization protocol used, the measurements of the gap between the tooth and the filling are very similar except for Z-100™/Astralis® 7, for which shrinkage results are more important. For any one resin composite and lamp used, the shrinkage values obtained at a depth of 4 mm are twice higher than those obtained at the surface. In conclusion, for a 3-second exposure the level of polymerization obtained by plasma curing is lower than the one obtained by halogen curing, particularly in depth. On the other hand, 5-second plasma curing results recommends the use of this kind of lamp.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 2 van 8 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland