  Biomechanical comparison of newly designed stemless prosthesis and conventional hip prosthesis - An experimental study
 
 
Titel: Biomechanical comparison of newly designed stemless prosthesis and conventional hip prosthesis - An experimental study
Auteur: Ching-Lung Tai
Mel S. Lee
Weng-Pin Chen
Pang-Hsin Hsieh
Po-Chen Lee
Chun-Hsiung Shih
Verschenen in: Bio-medical materials and engineering
Paginering: Jaargang 15 (2005) nr. 3 pagina's 239-249
Jaar: 2005-05-23
Inhoud: Local bone loss after implantation of traditional stem-type prostheses remains an unsolved problem during the long-term application of total hip replacement. The stress shielding effect and osteolysis were thought to be the two main factors that result in local bone loss after prosthesis implantation. A newly designed stemless cervico-trochanteric (C-T) prosthesis was thus developed to reduce stress shielding and osteolysis caused by the implantation of conventional stem-type prosthesis. Eight synthetic femora were implanted with C-T and porous coated anatomic (PCA) prostheses. Under 2,000-Newton load, the surface strains of proximal femora were compared between the intact, PCA press-fit femora and the C-T implanted femora with three different fixation modes: two-screw fixation, three-screw fixation, and three-screw combined with cement fixation. The results revealed that stress shielding in the C-T implanted femora was significantly eliminated compared to that of the PCA implanted femora (p<0.01). No statistical difference in strain magnitude was found for the C-T implanted femora among the three different fixation modes (p>0.1). The C-T implanted femur has more physiological strain distribution. Moreover, from the C-T prosthetic characteristic design, the localized osteolysis would be also reduced due to the overall coverage of neck-trochanteric area. The newly designed C-T prosthesis may be a useful alternative to the traditional stem-type prosthesis in the future.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 4 van 10 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland