Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 10 van 11 gevonden artikelen
 
 
  The effect of low intensity pulsed ultrasound on regenerate bone in a less-than-rigid biomechanical environment
 
 
Titel: The effect of low intensity pulsed ultrasound on regenerate bone in a less-than-rigid biomechanical environment
Auteur: M. Shaun Machen
John E. Tis
Nozomu Inoue
Rainer H. Meffert
Edmund Y.S. Chao
Kathleen A. McHale
Verschenen in: Bio-medical materials and engineering
Paginering: Jaargang 12 (2002) nr. 3 pagina's 239-247
Jaar: 2002-10-28
Inhoud: The purpose of this study was to investigate effects of low intensity pulsed ultrasound (LIPU) on distraction osteogenesis in a less-than-rigid biomechanical environment in a rabbit model. A less-rigid mini-lengthener was applied and a mid-tibial osteotomy performed in 20 New Zealand White rabbits. After a 7 day latency period, the tibiae were distracted 0.5 mm every 12 hours for 10 days. Ten of the rabbits received LIPU for 20 min/day (ultrasound group) and 10 received sham LIPU (control group) from day 17 until sacrifice on day 37. Radiographs were taken weekly after distraction and the callus area was measured. After sacrifice, dual-energy X-ray absorptiometry (DEXA), torsional testing to failure, and histomorphometry were performed. On radiographs, all the treatment tibiae displayed persistent radiolucencies; however, only one of the control tibiae displayed a radiolucent interzone. Torsional strength of the treatment group was 54% of the contralateral tibia compared to 139% in the control group (p<0.008). Bone density and callus size were not significantly different between the 2 groups; however, the ultrasound group displayed a tendency towards more cartilage and fibrous tissue formation (p<0.16) and less bone (p<0.16) than controls. In a biomechanically unstable environment, LIPU appears to stimulate more cartilage formation in regenerated callus than in controls. This callus is biomechanically inferior to unstimulated callus at the early stage of healing tested. During distraction osteogenesis a sound biomechanical environment is important to achieving anticipated results.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 10 van 11 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland