Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 3 van 14 gevonden artikelen
 
 
  Correlation of grade of urothelial cell carcinomas and DNA histogram features assessed by flow cytometry and automated image cytometry
 
 
Titel: Correlation of grade of urothelial cell carcinomas and DNA histogram features assessed by flow cytometry and automated image cytometry
Auteur: Marco G.W. Bol
Jan P.A. Baak
Bianca v. Diermen
E.A.M. Janssen
Susanne B.K. Buhr-Wildhagen
Kjell-Henning Kjellevold
Verschenen in: Analytical cellular pathology
Paginering: Jaargang 25 (2003) nr. 3 pagina's 147-153
Jaar: 2003-11-11
Inhoud: Objective: To analyse how DNA ploidy and S-phase fraction (SPF) by flow cytometry (FCM) and an optimised fully automatic DNA image cytometer (ICM) correlate with grade in TaT1 urothelial cell carcinomas (UC) of the urinary bladder. Materials and methods: Two-hundred-and twenty-eight consensus cases were analysed. Single cell suspensions were stained (DAPI for FCM, Feulgen for ICM). There was enough material for both FCM and ICM in 202 of these cases. FCM and optimised ICM measurements were performed on the 202 UCs. To discriminate between different grades, single- and multivariate analyses was performed on DNA histogram features obtained with the MultiCycle program (using DNA index (DI) and SPF). Results: Overall measurement time of the adapted ICM method was 10.7 minutes per case (range 5.9-29.8 min.) and required little additional interactive object rejection (average 152 objects (84-298) on 3000 objects per case measured, which took 9.9 minutes on average, range 8.3-15.5 minutes). The ICM histograms looked much "cleaner" with less noise than the FCM graphs. The coefficient of variation (CV) of the diploid peak for ICM (5.4%) was significantly lower than for FCM (5.9%) (p<0.0001). ICM features were more strongly correlated to grade than FCM features. In multivariate analysis, the best discriminating set of features was DNA ploidy and SPF (both by ICM). Conclusions: The adapted fully automated DNA ICM works very well for UCs. Low CV DNA ICM histograms are obtained in a time comparable to FCM. The DNA ICM results have stronger discriminative power than DNA FCM for grade in TaT1 UCs. Colour figures can be viewed on http://www.esacp.org/acp/2003/25-3/bol.htm
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 3 van 14 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland
Toegankelijkheidsverklaring