  The viscous characterization of hydroxyethyl starch (HES) plasma volume expanders in a non-Newtonian blood analog
 
 
Titel: The viscous characterization of hydroxyethyl starch (HES) plasma volume expanders in a non-Newtonian blood analog
Auteur: Walker, Andrew M.
Xiao, Yao
Johnston, Clifton R.
Rival, David E.
Verschenen in: Biorheology
Paginering: Jaargang 50 (2013) nr. 3-4 pagina's 177-190
Jaar: 2013-07-17
Inhoud: Although information pertaining to the viscous characterization of HES 130/0.4 Voluven® and HES 260/0.45 Pentaspan® is available, quantification is limited to 100% concentrations. We focus here on the quantification of their viscous behavior along with HES 130/0.4 Volulyte® in a shear thinning non-Newtonian blood analog of aqueous xanthan gum and glycerol. Dynamic viscosities of multiple batches of HES fluids were measured through capillary viscometry. The viscous behavior of 100%, 25% and 12.5% concentrations were then measured through a closed flow loop across physiologically relevant flow rates. Measured viscosities were 2.57 millipascal second (mPa·s) 6.52 mPa·s and 2.48 mPa·s for HES 130/0.4 Voluven®, HES 260/0.45 and HES 130/0.4 Volulyte®, respectively. Pipe flow analysis found that all HES fluids displayed Newtonian behavior at 100% concentrations. 25% concentrations of both HES 130/0.4 fluids decreased analog viscosity 23%–29% at a flow rate of 1.0 ml/s and 16%–21% at a flow rate of 22.5 ml/s. At a flow rate of 22.5 ml/s, 25% and 12.5% concentrations of HES 260/0.45 resulted in analog viscosity changes of 3.9%–4.5%. Capillary viscosity reductions of approximately 7% and 14.5% in HES 130/0.4 Voluven® and HES 260/0.45 suggest changes in molecular composition to batches previously measured. Maintenance of analog viscosity suggests that HES 260/0.45 would be suitable as a high viscosity plasma expander in extreme hemodilution through preservation of microcirculatory function and wall shear stress (WSS).
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 9 van 9 gevonden artikelen
 
<< vorige   
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland