nr |
titel |
auteur |
tijdschrift |
jaar |
jaarg. |
afl. |
pagina('s) |
type |
1 |
A biomechanical analysis of aortic valve histology
|
Sauren, A.A.H.J. |
|
1980 |
13 |
9 |
p. 810-811 2 p. |
artikel |
2 |
A comparative investigation into the mechanical properties of different external devices
|
Haarman, H.J. |
|
1980 |
13 |
9 |
p. 800-801 2 p. |
artikel |
3 |
A kinetic study of lower limb mechanics
|
Andriacchi, T.P. |
|
1980 |
13 |
9 |
p. 805-806 2 p. |
artikel |
4 |
All carbon joint prostheses (mechanical and tribological properties)
|
Brückmann, H. |
|
1980 |
13 |
9 |
p. 810- 1 p. |
artikel |
5 |
A material for the substitution of cortical bone in biomechanical simulation experiments
|
de Wun, J.R. |
|
1980 |
13 |
9 |
p. 806- 1 p. |
artikel |
6 |
A mathematical and experimental model of the metacarpus phalanx joint
|
Tranquilli-Leali, P. |
|
1980 |
13 |
9 |
p. 810- 1 p. |
artikel |
7 |
A mathematical model for distribution of contact pressures in total hip prosthesis
|
Crolet, J.M. |
|
1980 |
13 |
9 |
p. 807- 1 p. |
artikel |
8 |
Analysis of the behaviour of the intervertebral disc under different types of load as measured by the intranuclear pressure
|
Robert, H. |
|
1980 |
13 |
9 |
p. 798- 1 p. |
artikel |
9 |
An experimental implant system for traumatic instability of the dorso-lumbar spine
|
Jacobs, R.R. |
|
1980 |
13 |
9 |
p. 801- 1 p. |
artikel |
10 |
Application of the 2 transform to biological impedance measurements
|
Pegoff, S. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
11 |
Biomechanical analysis of a knee joint; Spatial kinematic measurements
|
Landjerit, B. |
|
1980 |
13 |
9 |
p. 810- 1 p. |
artikel |
12 |
Biomechanical aspects of fracture healing in experimental uremia
|
Geiger, G. |
|
1980 |
13 |
9 |
p. 798- 1 p. |
artikel |
13 |
Biomechanical evaluation of means of fixation of the fracture of the neck of the femur
|
Burny, F. |
|
1980 |
13 |
9 |
p. 802- 1 p. |
artikel |
14 |
Biomechanical problems of knee joint prosthesis demonstrated on our experiences with the Guepar-prosthesis
|
Scholz, J. |
|
1980 |
13 |
9 |
p. 809- 1 p. |
artikel |
15 |
Biomechanical studies on plate prebending and tensioning and on the stability of compression osteosynthesis
|
Gotzen, L. |
|
1980 |
13 |
9 |
p. 803- 1 p. |
artikel |
16 |
Biomechanical study of mandibular osteosynthesis
|
Champy, M. |
|
1980 |
13 |
9 |
p. 803- 1 p. |
artikel |
17 |
Biomechanics: Applications, costs and benefits, priorities
|
|
|
1980 |
13 |
9 |
p. 737-743 7 p. |
artikel |
18 |
Blood compatibility of elastomers for leaflet heart valves
|
Hoffacker, W. |
|
1980 |
13 |
9 |
p. 811- 1 p. |
artikel |
19 |
Bone growth stimulation—Critique and one point
|
Steinemann, S.G. |
|
1980 |
13 |
9 |
p. 803- 1 p. |
artikel |
20 |
Bone remodelling
|
Steinemann, S.G. |
|
1980 |
13 |
9 |
p. 798- 1 p. |
artikel |
21 |
Bone remodelling and its effect on the biomechanical properties of cortical bone after rigid plate fixation
|
Paavolainen, P. |
|
1980 |
13 |
9 |
p. 798- 1 p. |
artikel |
22 |
Bone screw displacement under lateral loading
|
Martin, D. |
|
1980 |
13 |
9 |
p. 799- 1 p. |
artikel |
23 |
Callus formation and asymmetric voltage stimulation
|
Aro, H. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
24 |
Carbon and glass fiber-reinforced uhmwpe for endoprostheses
|
Sahm, K.F. |
|
1980 |
13 |
9 |
p. 810- 1 p. |
artikel |
25 |
Closed pressurization of medullary cement in total hip replacement
|
Oh, I. |
|
1980 |
13 |
9 |
p. 812- 1 p. |
artikel |
26 |
Comparative evaluation of some mechanical properties of the callus produced either with standard plate or intramedullary nail fixation
|
Sedel, L. |
|
1980 |
13 |
9 |
p. 798- 1 p. |
artikel |
27 |
Contact areas and distribution of the load in the tibio-femoral joint
|
Guida, G. |
|
1980 |
13 |
9 |
p. 811- 1 p. |
artikel |
28 |
Critical analysis of in vivo measurement using strain gauges
|
Burny, F. |
|
1980 |
13 |
9 |
p. 802-803 2 p. |
artikel |
29 |
Direct and indirect analysis of shear dependence of reversible erythrocyte orientation and aggregation
|
Quemada, D. |
|
1980 |
13 |
9 |
p. 811- 1 p. |
artikel |
30 |
Direct measurement of hip joint forces in sheep
|
Bergmann, G. |
|
1980 |
13 |
9 |
p. 805- 1 p. |
artikel |
31 |
Dynamic analysis of growth activity at the epiphyseal plate
|
Bonnel, F. |
|
1980 |
13 |
9 |
p. 797- 1 p. |
artikel |
32 |
Effects of pressurization on the intrusion and mechanical properties of PMMA
|
Merckx, D.B. |
|
1980 |
13 |
9 |
p. 812- 1 p. |
artikel |
33 |
Elbow joint force predictions for some strenuous isometric actions
|
Amis, A.A. |
|
1980 |
13 |
9 |
p. 765-775 11 p. |
artikel |
34 |
Electrical gait simulation—A new method for affected bone repair
|
Jansons, H. |
|
1980 |
13 |
9 |
p. 812- 1 p. |
artikel |
35 |
Electrochemical information transfer via pulsing electromagnetic fields
|
Pilla, A.A. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
36 |
Electrochemical study of the electrodes' behaviour during bioelectric impedance measurements
|
Georges, B. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
37 |
Electrode induced bone growth: The role of the electrode material
|
Spadaro, J.A. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
38 |
Electrodynamic stimulation of rabbit femora. An attempt to standardize a clinically practicable method
|
Luisto, Markku D. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
39 |
Electromagnetic and electric field configuration produced by two coils
|
Dierickx, M. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
40 |
Electromagnetic modulation of fracture repair in the rat
|
Christel, P. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
41 |
Experience on hip joint replacement using a specially designed acetabular cup
|
Scholz, J. |
|
1980 |
13 |
9 |
p. 807- 1 p. |
artikel |
42 |
Experience on retropatellar facet replacement using the McKeever-patellar prosthesis
|
Hanslik, L. |
|
1980 |
13 |
9 |
p. 809-810 2 p. |
artikel |
43 |
Experimental study of the vibration and impact response of human tibiae by modal analysis
|
Van der Perre, G. |
|
1980 |
13 |
9 |
p. 797- 1 p. |
artikel |
44 |
Forces acting on the mandible during bilateral static bite at different bite force levels
|
Pruim, G.J. |
|
1980 |
13 |
9 |
p. 755-763 9 p. |
artikel |
45 |
Forces and couples in the lumbar spine during running
|
Cappozzo, Aurelio |
|
1980 |
13 |
9 |
p. 806- 1 p. |
artikel |
46 |
Forces transmitted by the index finger and the thumb in selected activities
|
Purves, W.K. |
|
1980 |
13 |
9 |
p. 805- 1 p. |
artikel |
47 |
Functional structure and strength of the growth apparatus in normal and in uremic rats
|
Krempien, B. |
|
1980 |
13 |
9 |
p. 797- 1 p. |
artikel |
48 |
Heat generated in fatigued cortical bone specimens
|
Victoria, J. |
|
1980 |
13 |
9 |
p. 795-796 2 p. |
artikel |
49 |
Human control of the skateboard
|
Hubbard, Mont |
|
1980 |
13 |
9 |
p. 745-754 10 p. |
artikel |
50 |
Intramedullary nailing with reaming; A critical analysis of Kuntscher's principles
|
Kempf, I. |
|
1980 |
13 |
9 |
p. 800- 1 p. |
artikel |
51 |
In vitro histochemical modifications induced by electromagnetic stimulation
|
Rooze, M. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
52 |
In vivo measurement of the mechanical properties of bone tissue
|
Burny, F. |
|
1980 |
13 |
9 |
p. 796- 1 p. |
artikel |
53 |
Locked-in acrylic cement stresses, caused by thermal shrinkage after fixation of intramedullary joint prostheses
|
Huiskes, R. |
|
1980 |
13 |
9 |
p. 808- 1 p. |
artikel |
54 |
Mechanical factors in (non-constrained) total knee arthroplasty: Concept and clinical consequences
|
Soudan, Karel |
|
1980 |
13 |
9 |
p. 809- 1 p. |
artikel |
55 |
Mechanical performances of intramedullary locking-in nailing of femur and tibia
|
Kempf, I. |
|
1980 |
13 |
9 |
p. 800- 1 p. |
artikel |
56 |
Mechanisms and results of non-union repair with pulsing electromagnetic fields
|
Bassett, C.A.L. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
57 |
Morphological effect of electromagnetic stimulation on the skeleton of new born mouse
|
Rooze, M. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
58 |
New approach in three dimensional analysis of scoliotic deformity
|
Graf, H. |
|
1980 |
13 |
9 |
p. 810- 1 p. |
artikel |
59 |
New glass ceramics for bone implants
|
Pernot, F. |
|
1980 |
13 |
9 |
p. 808- 1 p. |
artikel |
60 |
New models for articular cartilage and synovial fluid with application to the knee joint
|
Droogendijk, L. |
|
1980 |
13 |
9 |
p. 797- 1 p. |
artikel |
61 |
Non-invasive out patient treatment of surgically-resistant non-unions by induced pulsing current; Clinical results
|
Mulier, J.C. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
62 |
Optimization of osteosynthesis with external fixation devices
|
Constant, T. |
|
1980 |
13 |
9 |
p. 803- 1 p. |
artikel |
63 |
Oscillating flow between a clot model and a stenosis
|
Doffin, J. |
|
1980 |
13 |
9 |
p. 811- 1 p. |
artikel |
64 |
Possibilities and limitations for the fixation of bone, joint and tooth replacements: Some general considerations
|
Heimke, G. |
|
1980 |
13 |
9 |
p. 808-809 2 p. |
artikel |
65 |
Principal parameters in the mechanical performance of intramedullary fixated artificial joints
|
Huiskes, R. |
|
1980 |
13 |
9 |
p. 806-807 2 p. |
artikel |
66 |
Proposal for a new method of mettallic osteosynthesis to be used in cases of undercapitatis femoral fractures
|
Fedi, C. |
|
1980 |
13 |
9 |
p. 803- 1 p. |
artikel |
67 |
Quantitative image analysis of cortical bone sections for determination of tension and torsion strength
|
Walk, H. |
|
1980 |
13 |
9 |
p. 798- 1 p. |
artikel |
68 |
Recent experimental and clinical results of the electrodynamic field-therapy (Draus-Lechner)
|
Lechner, F. |
|
1980 |
13 |
9 |
p. 803- 1 p. |
artikel |
69 |
Reduction of axial plate screw force in a cortical bone static and dynamic loading mode
|
Brümmer, H. |
|
1980 |
13 |
9 |
p. 799- 1 p. |
artikel |
70 |
Relationship between plate-bone contact area and blood supply in internal fixation
|
Luethi, U. |
|
1980 |
13 |
9 |
p. 799-800 2 p. |
artikel |
71 |
Reversible and irreversible deformation in bone microhardness
|
Rahn, B.A. |
|
1980 |
13 |
9 |
p. 796- 1 p. |
artikel |
72 |
Rough surfaced plate: Mechanical and biological effect on intact dog's femur
|
Moyen, B. |
|
1980 |
13 |
9 |
p. 800- 1 p. |
artikel |
73 |
Short term bonding behaviour of bioglass coatings on metal substrate
|
Ducheyne, P. |
|
1980 |
13 |
9 |
p. 807-808 2 p. |
artikel |
74 |
Some energetic criterions as bone callus maturity signs
|
Puritis, J. |
|
1980 |
13 |
9 |
p. 811- 1 p. |
artikel |
75 |
Some kinematic characteristics of the human knee-joint, a roentgenstereophotogrammetrical study
|
de Lange, A. |
|
1980 |
13 |
9 |
p. 805- 1 p. |
artikel |
76 |
Stability and strength provided by internal fixation systems for dorso-lumbar spinal injuries
|
Jacobs, R.R. |
|
1980 |
13 |
9 |
p. 802- 1 p. |
artikel |
77 |
Strength of cortical bone following osteotomy under internal plate fixation or plaster cast treatment
|
Hutzschenreuter, P. |
|
1980 |
13 |
9 |
p. 798- 1 p. |
artikel |
78 |
The acetabular cement compactor: An improvement in cementing technique in total hip replacement
|
Oh, I. |
|
1980 |
13 |
9 |
p. 812- 1 p. |
artikel |
79 |
The anchorage of carbon-fibre-strands into bone, a biomechanical and biological evaluation on knee-joints
|
Neugebauer, R. |
|
1980 |
13 |
9 |
p. 809- 1 p. |
artikel |
80 |
The causality of elastic, electrical and magnetic forces in the healthy and the defective bone
|
Kraus, W. |
|
1980 |
13 |
9 |
p. 803- 1 p. |
artikel |
81 |
The development of a new external fixation device for compound fractures of the tibia
|
Goudfrooy, H. |
|
1980 |
13 |
9 |
p. 801- 1 p. |
artikel |
82 |
The development of major prosthetic replacements for tumours and other conditions affecting the long bones
|
Scales, J.T. |
|
1980 |
13 |
9 |
p. 811- 1 p. |
artikel |
83 |
The effects of surgical preparation on acetabular cup fixation
|
Pawluk, R.J. |
|
1980 |
13 |
9 |
p. 810- 1 p. |
artikel |
84 |
The elasticity of various carbon fibre ligament prostheses
|
Claes, L. |
|
1980 |
13 |
9 |
p. 810- 1 p. |
artikel |
85 |
The function of the primary ligaments of the knee in anterior-posterior and medial-lateral motions
|
Piziali, Robert L. |
|
1980 |
13 |
9 |
p. 777-784 8 p. |
artikel |
86 |
The function of the primary ligaments of the knee in varus-valgus and axial rotation
|
Seering, Warren P. |
|
1980 |
13 |
9 |
p. 785-794 10 p. |
artikel |
87 |
Theoretical and experimental analysis of the stem-femur coupling: New improved procedures
|
Calderale, P.M. |
|
1980 |
13 |
9 |
p. 807- 1 p. |
artikel |
88 |
The prediction of postoperative compression in cortical bone screws
|
Cordey, J. |
|
1980 |
13 |
9 |
p. 799- 1 p. |
artikel |
89 |
The relationship between the swelling of cortical bone and its mineral content
|
Lipshitz, Harold |
|
1980 |
13 |
9 |
p. 795- 1 p. |
artikel |
90 |
The response of biological systems to electric currents induced by pulsed magnetic fields
|
Fitton Jackson, S. |
|
1980 |
13 |
9 |
p. 804- 1 p. |
artikel |
91 |
The use of gauges to determine in vivo load on a spinal external fixation device
|
Schlaepfer, F. |
|
1980 |
13 |
9 |
p. 801- 1 p. |
artikel |
92 |
Three dimensional finite element analysis and experimental investigation of strain in the femur with and without prosthetic replacement
|
Rohlmann, A. |
|
1980 |
13 |
9 |
p. 806- 1 p. |
artikel |
93 |
Time dependence analysis of mechanical properties of cortical bone
|
Victoria, J. |
|
1980 |
13 |
9 |
p. 796- 1 p. |
artikel |