  Eficiência de um conjunto fotovoltaico em condições reais de trabalho na região de Cascavel = Efficiency of the photovoltaic systems under real work conditions on region of Cascavel
 
 
Titel: Eficiência de um conjunto fotovoltaico em condições reais de trabalho na região de Cascavel = Efficiency of the photovoltaic systems under real work conditions on region of Cascavel
Auteur: Estor Gnoatto
Rivanildo Dallacort
Reinaldo Prandini Ricieri
Suedemio de Lima Silva
Yuri Ferruzi
Verschenen in: Acta scientiarum. Technology
Paginering: Jaargang 30 (2008) nr. 2 pagina's 215-219
Jaar: 2008
Inhoud: No presente trabalho, foi desenvolvido um estudo sobre um sistemafotovoltaico autônomo, com armazenamento de energia, instalado na Estação Experimental Agrometeorológica da Universidade Estadual do Oeste do Paraná, Campus Cascavel, a uma Latitude 24º59’ Sul, Longitude de 53º26’ Oeste, com altitude de 682 m, em condições reaisde campo, durante o ano de 2002. Foi avaliada a eficiência dos painéis fotovoltaicos em condições reais de campo, sua curva característica foi determinada utilizando, na aquisição de dados, um micrologger da Campbell Scientific-Inc, modelo CR10X, programado pararealizar uma leitura por segundo de cada canal e armazenar a média aritmética de 5 minutos dos dados das componentes de radiação solar global no plano horizontal e global na incidência do painel; temperatura ambiente e temperatura de operação do painel; tensão ecorrente do sistema fotovoltaico. Os resultados mostram que a eficiência média mensal registrou valores na faixa de 8,65 a 9,17%, com uma média de 8,84%, com variação percentual entre o índice máximo e mínimo de 5,67%. Pode, assim, representar fornecimento médio mensal de energia de 5,57 kWh por painel.The purpose of the present work was to develop a study of anautonomous photovoltaic system, with energy storage, installed at the Experimental Agrometeorological Station of the Universidade Estadual do Oeste do Paraná, Cascavel Campus, located at 24º59’S 53º26’W, 682 meters of altitude, under real field conditions, during the year of 2002. The efficiency of the photovoltaic modules was evaluated underreal field conditions and its characteristic linear fit was determined. A Campbell Scientific CR10X micrologger was used to acquire data, programmed to conduct one reading per second from each channel and store the five-minute arithmetic data average from thereadings of the incidence of global direct solar radiation horizontal and global) on the panel, as well as area temperature, panel operational temperature, photovoltaic system tension and current. The results show that average monthly efficiency registered values in the range from 8.65 to 9.17%, with and average of 8.84%, and variation of 5.67%. Therefore, this array can supply a monthly average of 5.57 kWh per panel.
Uitgever: Editora da Universidade Estadual de Maringá (provided by DOAJ)