Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 14 van 15 gevonden artikelen
 
 
  The bioaccessibility of lead from Welsh mine waste using a respiratory uptake test
 
 
Titel: The bioaccessibility of lead from Welsh mine waste using a respiratory uptake test
Auteur: Wragg, Joanna
Klinck, Ben
Verschenen in: Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering
Paginering: Jaargang 42 (2007) nr. 9 pagina's 1223-1231
Jaar: 2007-01
Inhoud: The objective of this study was to develop an in vitro respiratory uptake test to determine the bioaccessibility of lead derived from mining waste tailings and dusts. Samples were collected from an abandoned mining area in mid-Wales, UK, the < 10 μ m fraction was characterized using SEM and the < 100 μ m fraction using XRD techniques. Gamble's Solution was employed as the synthetic lung fluid and tests were run for 630 hours in a specially designed water bath. The long test duration was specified because of the long duration of particulates in the lung after inhalation. Bioaccessible lead was determined throughout the test and the final values ranged from 15 to 41% of total lead. The extraction profile of the lead could be modeled by: Pb - extracted (M) = b × ln (time, t) + c, where b and c are sample specific constants, M is the mass extracted in mg and t is the time in hours. However, despite acceptable values of R2, the standardised residuals of simple regression suggest that lead extracted is under predicted at early time and over predicted at later time. Clearly from the regression model presented the dissolution rate is declining with time and the dissolution rate decreases by an order of magnitude for the tailings tested over the duration of the test. The explanation for this is the deposition of an insoluble lead phosphate mineral during the extraction onto lead mineral surfaces that effectively limits dissolution. Based on this finding it is suggested that the in vitro extraction method described can provide a conservative estimate of bioaccessible lead for a shorter duration test of 100 hours.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 14 van 15 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland