Digitale Bibliotheek
Sluiten Bladeren door artikelen uit een tijdschrift
 
<< vorige    volgende >>
     Tijdschrift beschrijving
       Alle jaargangen van het bijbehorende tijdschrift
         Alle afleveringen van het bijbehorende jaargang
           Alle artikelen van de bijbehorende aflevering
                                       Details van artikel 11 van 26 gevonden artikelen
 
 
  Evaluation of the B-method for determining actual evapotranspiration in a boreal forest from MODIS data
 
 
Titel: Evaluation of the B-method for determining actual evapotranspiration in a boreal forest from MODIS data
Auteur: Sanchez, J. M.
Caselles, V.
Niclos, R.
Valor, E.
Coll, C.
Laurila, T.
Verschenen in: International journal of remote sensing
Paginering: Jaargang 28 (2007) nr. 6 pagina's 1231-1250
Jaar: 2007-01
Inhoud: Boreal forests occupy about 11% of the terrestrial surface and represent an important contribution to global energy balance. The ground measurement of daily evapotranspiration (LEd) is very difficult due to the limitations on experiments. The objective of this paper is to present and explore the applicability of the B-method for monitoring actual LEd in these ecosystems. The method shown in this paper allows us to determine the surface fluxes over boreal forests on a daily basis from instantaneous information registered in a conventional meteorological tower, as well as the canopy temperature (T c) retrieved by satellite. Images collected by the MODIS (moderate resolution imaging spectroradiometer) on board EOS-Terra have been used for this study. The parameters of the model were calibrated from the SIFLEX-2002 (Solar Induced Fluorescence Experiment 2002) campaign dataset in a northern boreal forest in Finland. A study of these parameters was made on an hourly basis in order to make the method applicable, not only at midday but within an interval of 7 h around it. This is an important advance with respect to the original formulation of this approach since the overpass time of satellites can be very variable. The comparison between T c ground measured with a thermal infrared radiometer, and T c retrieved from land surface temperature (LST) MODIS data, showed an estimation error of ±1.4°C for viewing angles from 5 to 60°. A complete sensitivity analysis was carried out and an estimation error of about ±35%, corresponding to the interval 10.00-11.00 h UTC, was shown as the lowest in LEd retrieval. Finally, the method was validated over the study site using 21 MODIS images for 2002 and 2003. The results were compared with eddy-correlation ground measurements. An accuracy of ±1.0 mm/day and an overestimation of 0.3 mm/day were shown in the LEd retrieval.
Uitgever: Taylor & Francis
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 11 van 26 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland