  Using a spine stabilizer instrument to control postural sway in standing lumbar curvature measurements by flexible curve
 
 
Titel: Using a spine stabilizer instrument to control postural sway in standing lumbar curvature measurements by flexible curve
Auteur: Seidi, Foad
Minoonejad, Hooman
Youdas, James W.
Verschenen in: Journal of back and musculoskeletal rehabilitation
Paginering: Jaargang 28 (2014) nr. 2 pagina's 311-316
Jaar: 2014-08-05
Inhoud: BACKGROUND AND OBJECTIVE: The amount of postural sway and sagittal deviation of lumbar lordosis angle in measurements of standing lumbar curvature obtained by flexible curve can be decreased when using a spine stabilizer instrument. However, this assumption has not been investigated so far. This study aims to determine the effect of using a spine stabilizer instrument on the validity, reliability, and standard errors of measurement of flexible curve in the standing lumbar curvature measurements. MATERIAL AND METHOD: Thirty-four volunteer men aged between 19 and 30 years participated in the study By using a 50-cm flexible curve, with and without spine stabilizer instrument, and a lumbar simple lateral radiograph (LSLR), the standing lumbar curvature was measured by three methods for each subject. These methods were called A, B and C, respectively. RESULTS: By using the Pearson's correlation analysis at significance level of 0.05, the coefficient of correlation between standing lumbar curvature measurements in methods A and B with C were 0.95 and 0.84, respectively. In addition, the intraclass correlation coefficient for methods A and B were 0.94 and 0.79, respectively. Also, results of the one-way analysis of variance for comparison of pairs indicated a significant difference in the mean values of standing lumbar curvature angles between methods B and C. CONCLUSIONS: Results indicated the flexible curve was an appropriate instrument for standing lumbar curvature measurements. Using spine stabilizer instrument to control postural sway increases the validity and reliability of flexible curve method and decreases its standard errors of measurement.
Uitgever: IOS Press
Bronbestand: Elektronische Wetenschappelijke Tijdschriften
 
 

                             Details van artikel 49 van 56 gevonden artikelen
 
<< vorige    volgende >>
 
 Koninklijke Bibliotheek - Nationale Bibliotheek van Nederland